MAINTENANCE
5700XP 331533 (9--06)
58
6. Plug the charger connector into the battery
connector.
WARNING: Batteries emit hydrogen
gas. Explosion or fire can result. Keep
sparks and open flame away. Keep
covers open when charging.
7. Plug the battery charger into the wall outlet.
NOTE: If the red “ABNORMAL CYCLE” lamp
lights when the TENNANT charger is plugged into
a wall outlet, the charger cannot charge the
battery and there is something wrong with the
battery.
8. The TENNANT charger will start
automatically. When the batteries are fully
charged, the TENNANT charger will
automatically turn off.
9. After the charger has turned off, unplug the
charger from the wall outlet.
10.Unplug the charger connector from the
battery connector on the machine.
FOR SAFETY: When maintaining or
servicing machine, avoid contact with
battery acid.
11. Check the electrolyte level in each battery
cell after charging. If needed, add distilled
water to raise the electrolyte level to about
12 mm (0.4 in) below the bottom of the sight
tubes.
12. Lower the solution tank.
13. Pull up on the support arm and rotate the
stop arm out of the way to allow the solution
tank to close completely.