background image

OPERATION

EN

Tennant 2550 (02--01)

9

WHILE OPERATING MACHINE

1. Always operate with caution when burnishing

around walls and obstacles.

2. Always reduce speed to maintain control when

turning.

3. Stay clear of floor obstructions, such as electrical

plates or grates, they will destroy pad. Tilt machine

back to avoid floor obstructions.

NOTE:

When machine is tilted back completely,

power to pad motor automatically shuts off.

4. Change or turn pads over when soiled.
5. Check battery meter’s discharge level periodically.

Recharge when needle drops to the red zone.

ATTENTION: Do not operate machine in red zone,

floor damage and brush motor overload may

result.

6. If pad motor circuit breaker trips, reduce pad

pressure and/or replace soiled pad.

FOR SAFETY: Before leaving or servicing

machine, stop on level surface, turn off machine

and set parking brake.

FOR SAFETY: When transporting machine, do not

lift machine if batteries are installed.

EMERGENCY STOP SWITCH

To stop machine during an emergency, hit the red

emergency stop switch located at rear of control

console. The emergency stop switch immediately

stops all power to machine.
To reset emergency stop switch, shut off all switches

and turn red button to the right. Resume to normal

operation.

Emergency Stop Switch

CIRCUIT BREAKERS

Machine is equipped with two resettable circuit

breakers, Main (15A) and Pad Motor (80A), to protect

machine from damage. If pad motor circuit breaker

should trip, determine cause, allow motor to cool, then

reset. Pad circuit breaker will trip due to excessive pad

overload. Change pad or reduce pad pressure if

breaker should trip. Pad motor circuit breaker button is

located under battery hood at front of machine.

Resettable Circuit Breakers

CHARGING BATTERIES

NOTE:

Recharge batteries ONLY after a total of 30

minutes of use or more. This will prolong battery life.

The following charging instructions are intended

for supplied 36V chargers only. Only use a

charger with the following specifications to

prevent battery damage.

CHARGER SPECIFICATIONS:

S

OUTPUT VOLTAGE - 36 VOLTS

S

OUTPUT CURRENT - 25 AMPS MAXIMUM

S

AUTOMATIC SHUTOFF CIRCUIT

S

FOR DEEP CYCLE BATTERY CHARGING

NOTE:

For optimum machine operation, keep

batteries charged at all times. Never let batteries set in

a discharge condition for lengthy periods.

WARNING: Batteries emit hydrogen gas.

Explosion or fire can result. Keep sparks and

open flame away. Keep battery compartment open

when charging.

FOR SAFETY: When servicing machine, wear

protective gloves when handling batteries or

battery cables. Avoid contact with battery acid.

Содержание 2550

Страница 1: ...Operator Manual Dust Control Burnisher English EN 2550 611581 Rev 01 05 2006 Model Part No M611373 611581 www tennantco com ...

Страница 2: ...mentally way according to your local waste disposal regulations Always remember to recycle TENNANT N V Industrielaan 6 5405 AB P O Box 6 5400 AA Uden The Netherlands europe tennantco com www tennantco com Specifications and parts are subject to change without notice Copyright E2001 2006 Tennant Company All rights reserved MACHINE DATA Please fill out at time of installation for future reference Mo...

Страница 3: ...L BAG 7 ADJUSTING CONTROL GRIP HEIGHT 7 MACHINE OPERATION 8 PRE OPERATION 8 BURNISHING WITH THE MACHINE 8 WHILE OPERATING MACHINE 9 EMERGENCY STOP SWITCH 9 CIRCUIT BREAKERS 9 CHARGING BATTERIES 9 MACHINE MAINTENANCE 10 DAILY MAINTENANCE 11 WEEKLY MAINTENANCE 11 MONTHLY MAINTENANCE 11 QUARTERLY MAINTENANCE 11 BATTERY MAINTENANCE 12 TRANSPORTING MACHINE 12 STORING MACHINE 12 RECOMMENDED STOCK ITEMS ...

Страница 4: ...arting machine Make sure all safety devices are in place and operate properly 3 When using machine Go slow on inclines and slippery surfaces Use care when reversing machine Always follow safety and traffic rules Report machine damage or faulty operation immediately 4 Before leaving or servicing machine Stop on level surface Turn off machine Set parking brake 5 When servicing machine Avoid moving p...

Страница 5: ...t Breaker Button 12 Key Switch 13 Emergency Stop Switch 14 Hour Meter 15 Rear Tilt Wheels for pad installation 16 Automatic Safety Shut Off Switch for pad installation 17 Dust Control Bag Compartment 18 Wall Rollers 19 Battery Compartment Hood 20 Battery Charge Plug 21 Pad Driver 22 Main Wheels 23 Parking Brake CONTROL PANEL SYMBOLS Main Power Pad Motor Circuit Breaker Main Power Circuit Breaker R...

Страница 6: ... for specific batteries Maximum battery dimensions are 78mm W x 394mm L x 362mm H FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine and set parking brake 1 Position machine on a level surface and set parking brake Set Parking Brake 2 Turn OFF all switches and remove key 3 Unlatch battery hood latches and open battery compartment Remove loose battery cables Open ...

Страница 7: ...extended time battery acid may leak 2 Remove the plastic centerlock from pad driver by squeezing the retainer clip on the centerlock 3 Position pad centered on pad driver and replace centerlock securely Installing Pad ATTENTION Do not operate machine without a pad and or centerlock in place 4 After installing pad return machine to operating position INSTALLING DUST CONTROL BAG 1 Open dust control ...

Страница 8: ...desired cleaning speed Twist Grips to Burnish FOR SAFETY When using machine go slow on inclines and slippery surfaces 5 Adjust pad pressure meter within Green Zone Press the Pad Pressure switch to decrease or increase pressure For best results adjust needle as shown Meter Needle GREEN ZONE RED ZONE Pad Pressure Meter ATTENTION Do not operate machine in red zone floor damage and brush motor overloa...

Страница 9: ...d turn red button to the right Resume to normal operation Emergency Stop Switch CIRCUIT BREAKERS Machine is equipped with two resettable circuit breakers Main 15A and Pad Motor 80A to protect machine from damage If pad motor circuit breaker should trip determine cause allow motor to cool then reset Pad circuit breaker will trip due to excessive pad overload Change pad or reduce pad pressure if bre...

Страница 10: ...rging Batteries NOTE Once the charger is connected to the machine machine will become inoperable 6 Then plug charger s power supply cord into a grounded wall outlet FOR SAFETY Do not operate charger unless cord is properly grounded Grounded Grounding Edge hole Outlet Connect to Grounded Outlet 7 Charger will automatically begin charging and automatically shut off when fully charged 8 After charger...

Страница 11: ...tes of use or more This will prolong battery life WEEKLY MAINTENANCE Every 20 Hours of Use 1 Clean battery tops of corrosion See BATTERY MAINTENANCE 2 Check for loose or corroded battery cables MONTHLY MAINTENANCE Every 80 Hours of Use 1 Lubricate caster with a water resistant grease 2 Check machine for loose nuts and bolts 3 Check condition of dust skirt replace if worn Check Condition of Dust Sk...

Страница 12: ...ost protectant to terminals and cable connections 4 Check for loose or worn cables Replace if worn TRANSPORTING MACHINE When transporting machine by use of trailer or truck be certain to follow tie down procedures below ATTENTION Tilt machine back when loading and unloading to prevent dust skirt damage 1 Load machine using a recommended loading ramp NOTE If lifting machine you must remove batterie...

Страница 13: ...Center Faulty wiring Contact Service Center Faulty pad drive motor Contact Service Center Worn carbon brushes Contact Service Center Tilt safety switch is activated or faulty Lower machine from tilt position Drive motor does not operate or operates incorrectly Parking brake is set Release parking brake Faulty roll switch Contact Service Center Faulty speed control board or connection Contact Servi...

Страница 14: ...5 Kg 540 lb DRIVE SYSTEM 15 kWTransaxle DRIVE SPEED 0 73m 0 240 ft per min PAD WIDTH 508mm 20 in PAD MOTOR 36V 22kW 2000 rpm 80A 2238W PAD PRESSURE Variable 7 19 kg 15 40 lb DUST CONTROL BAG Cloth Bag 98 1 0 micron BATTERIES 3 215amp hour 12v deep cycle RUN TIME CONTINUOUS Up to 2 2 hours DECIBEL RATING AT OPERATOR S EAR INDOORS ON TILE 70dB A ...