OPERATION
Tennant 1530 (12--02)
19
TROUBLESHOOTING -- Continued
PROBLEM
CAUSE
SOLUTION
Poor vacuum recovery.
Recovery tank is full.
Empty recovery tank.
Float Shut-off screen inside recovery
tank is clogged.
Remove screen and clean.
Pickup vacuum shoe is clogged with
debris.
Clean pickup vacuum shoe.
Loose drain hose plug.
Tighten plug.
Vacuum hose connections are loose
or hose has a hole.
Push hose cuffs firmly on connections.
Replace hose if damaged.
Clogged vacuum hose.
Remove clogged debris.
Recovery tank inlet hole is obstructed. Empty recovery tank and tilt tank side-
ways to access inlet hole, remove ob-
struction.
Recovery tank cover is not in place.
Properly position lid.
Worn tank cover gasket.
Replace gasket.
Loose vacuum motor.
Contact Service Center.
Faulty actuator.
Contact Service Center.
SPECIFICATIONS
MODEL
1530
LENGTH
1270 mm (50 in)
WIDTH
559 mm (22 in)
HEIGHT
1067 mm (42 in)
WEIGHT
180 Kg (395 lb)
RECOVERY TANK CAPACITY
80 L (21 Gal)
SOLUTION TANK CAPACITY
113.6 L (30 Gal)
MAXIMUM CLEANING RATE
Surface Clean Mode: 1022 m
2
(11,000 sq ft) per hour
Deep Clean Mode: 511 m
2
per hour (5,500 sq ft)
MAXIMUM SPEED
Surface Clean Mode:30 m (100 ft) per minute
Deep Clean Mode: 15 m (50 ft) per minute
Travel Mode: 45 m (150 ft) per minute
CLEANING PATH WIDTH
483 mm (19 in)
DRIVE SYSTEM
120V Transaxle, .19 kw (.25 hp)
MAXIMUM RATED CLIMB
5
°
with full tanks / 9
°
with empty tanks
BRUSH MOTOR
120V, .25 h.p., 1800 rpm, 2800 brush rpm, 1.5 A, 186W
VACUUM MOTOR
120V, 1.63 h.p., 3--stage 5.7 in, 10A. 1200W
WATER LIFT / AIR FLOW
2972 mm (117 in) / 99cfm (2.80m
3
) per minute
PUMP
120V, 6.9 bar (100 psi), 3.8 L (1 gal.) per minute.
TOTAL POWER CONSUMPTION
120V, 14 Amps
POWER CORD LENGTH
23 m (75 ft)
DECIBEL RATING AT OPERATOR’S EAR,
INDOORS ON CARPET
72 dB(A)
Specifictions are subject to change without notice.