MACHINE TROUBLESHOOTING
Problem
Cause
Remedy
Trailing water -- poor or no
water pickup
Worn rear squeegee
Rotate or replace rear squeegee
blade
Rear squeegee out of adjustment
Adjust rear squeegee
Vacuum hose clogged
Flush vacuum hoses
Recovery tank full
Drain tank
Float stuck shutting off vacuum
Clean float
Debris caught on squeegee
Remove debris
Foam filling recovery tank
Empty recovery tank; use less or
change detergent
Vacuum hose to rear squeegee
disconnected or damaged
Reconnect or replace vacuum
hose
Recovery tank lid not seated on
the recovery tank
Reinstall recovery tank lid
Little or no solution flow to
fl
Solution tank empty
Fill solution tank
floor
Solution control cable broken or
out of adjustment
Replace and/or adjust cable
Solution supply lines plugged
Flush solution supply lines
Poor scrubbing performance
Debris caught on scrub brushes
Remove debris
Improper detergent or brushes
used
Check with TENNANT representa-
tive for advice
Worn scrub brushes
Replace scrub brushes
ES
t
system does not fill solu-
tion tank
Clogged solution pump or lines
Flush ES
t
system
Содержание 1465
Страница 1: ...1465 1480 1490 MM185 Rev 11 9 94 ...
Страница 10: ...SPECIFICATIONS 1465 1485 1490 MM185 9 90 1Ć2 ...
Страница 18: ...OPERATION 1465 1480 1490 MM185 9 90 2 2 ...
Страница 42: ...MAINTENANCE 1465 1480 1490 MM185 9 90 3Ć2 ...
Страница 49: ...MAINTENANCE 3Ć9 1465 1480 1490MM185 11 92 05097 ELECTRICAL SCHEMATIC ...
Страница 68: ...APPENDIX 1465 1480 1490 MM185 9 90 4Ć2 ...
Страница 70: ...APPENDIX 1465 1480 1490MM185 9 90 4Ć4 ...