OPERATION
9
Tennant 1240/1260 (04--02)
2. Remove and clean float shut--off screen, located in
recovery tank (Figure 12).
FIG. 12
3. Inspect spray pattern for plugging. If plugged,
remove spray tips and screens and soak them in
acetic acid solution for up to six hours. Do not use
pointed objects to unplug tips, damage will occur
(Figure 13).
FIG. 13
4. Vacuum out leftover solution in solution tank
(Figure 14).
FIG. 14
5. Remove and rinse solution tank screen
(Figure 15).
FIG. 15
6. Remove any entangled carpet fibers and debris
from brush (Figure 16).
FIG. 16
7. Remove any clogged debris in pick up head
(Figure 17).
FIG. 17
8. Inspect condition of the stainless steel pickup
shoes. For best pick up performance, the shoes
must touch the floor the entire length of the pickup
head. Repair or replace shoes as needed.
9. Inspect cord and cord grip for damage, replace if
damaged. Coil cord neatly after each use.