![Tenma 72-9375 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/tenma/72-9375/72-9375_operating-manual_1086570021.webp)
20
Electro-Magnetic Field Interference:
When field value is under 1V/m:
total accuracy = assigned ac 5% of the
range.
When field value is over 1V/m: there is no assigned
accuracy
Battery Deficiency: Display
Negative reading:Display
Overloading: Display:
OL
.
Equipped with full icons display
Manual / Auto ranging
Polarity: Automatically display
Dimensions (HxWxL): 179 x 88 x 39mm
Weight: 380g (including holster and battery)
Safety/Compliances:
IEC61010: CAT. II 1000V, CAT. III 600V overvoltage
and double insulation standard.
Certification:
Accuracy Specifications
Accuracy
±
a% r b digits
guarantee for 1
year
Operating temperature
23
±5
Relative humidity
<75%
Temperature coefficient: 0.1 x (specified accuracy) /
1
A. AC Voltage
Range
Resolution
Accuracy
Overload
Protection
4V
1mV
40V
10mV
400V
100mV
±(1%+5)
750V
1V ±(1.2%+5)
1000V DC
or 750V AC
continuous.
Remarks
:
Input impedance: approx. 10M .
Frequency response: 40Hz ~ 400Hz.
Displays effective value of sine wave (mean
value response).
72-9375: OPERATING MANUAL
Содержание 72-9375
Страница 1: ...110V P N 110401102691 72 9375 ...