Keep this manual in a safe place for quick reference at all times. 
 
This manual contains important safety and operation instructions for correct use of the power supply. Read through the manual and pay 
special 
attention to the markings and labels of this unit and equipment to be connected. 
 
Pay special attention to these two types of notices used in this manual. 
 

WARNING 

Failure to observe this warning may cause injury to persons and damage to power supply or connected equipment 

CAUTION 

Failure to observe this warning may result in damage to equipment and improper functioning of the power supply. 
 

WARNING: 

1.

 

Do not use this power supply near water.  

2.

 

Do not operate or touch this power supply with wet hands.  

3.

 

Do not open the casing of the power supply when it is connected to AC power source.  

4.

 

Refer all servicing to qualified service personnel only.  

5.

 

Before replacing the AC fuse first determine and correct the cause or the blown fuse. Replace the AC fuse with the same type and 
rating as the original fuse.  

 

CAUTION:  

1.

 

Use only a properly grounded AC power source.  

2.

 

This unit is for indoor use only.  

3.

 

Do not operate or place this unit in a humid or dusty environment, in direct sunlight or near any heat source.  

4.

 

Before plugging into AC power source, check with the rating label at the back of the unit.  

5.

 

Do not block ventilation openings on the unit.  

6.

 

This unit must be used within the specified rating. Continuous excessive loading may cause damage to the power supply. 

7.

 

The AC power cord must be at least 18AWG, and not exceed 3m in length.  

8.

 

Replacement fuse: T3AL250V (3A Time-Lag)  

 

Environmental condition requirements:  

1.

 

10-80% R.H.  

2.

 

Altitude up to 2000m  

3.

 

Installation category: CAT 2  

4.

 

Pollution degree: 2  

5.

 

Maximum supply voltage fluctuation: ±10% of specified operating voltage.  

 

 

 

Introduction   

This precision series of switch mode laboratory DC power supplies are ideal for test, measurement and service applications where tight 
voltage and current regulation are critical. Highly efficient switch mode design delivers outstanding performance from an extremely 
compact footprint. Unique separate output ON/OFF control allows voltage and current setting, with the supply output turned off.  
 

Features:

  

 

Backlit four digit LCD display  

 

Simultaneous display of voltage and current  

 

Auto selecting constant voltage (CV) and constant current (CC) modes  

 

Ultra quiet convection cooling  

 

Short circuit, overload, over voltage and thermal protection  

 

84% efficiency at maximum output  

 

RoHs compliant 

 
 
 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание 72-8340

Страница 1: ...y Series Instruction Manual Model 72 8340 1 0 60VDC 0 1 6A 72 8345 1 0 36VDC 0 3A 72 8350 1 0 20VDC 0 5A Copyright 2008 all rights reserved Tenma Test Equipment www tenma com Downloaded from Elcodis com electronic components distributor ...

Страница 2: ...ment in direct sunlight or near any heat source 4 Before plugging into AC power source check with the rating label at the back of the unit 5 Do not block ventilation openings on the unit 6 This unit must be used within the specified rating Continuous excessive loading may cause damage to the power supply 7 The AC power cord must be at least 18AWG and not exceed 3m in length 8 Replacement fuse T3AL...

Страница 3: ...put black 10 LCD isplay Panel Backlit panel shows CC CV Mode Output status Voltage and Current output Operation Ground Connection Depending on the application the power supply output terminals can be grounded to suit any one of the following conditions Negative Ground Black negative terminal is tied to the green GND terminal Positive Ground Red positive terminal is tied to the green GND terminal F...

Страница 4: ...s more current than the supply is capable or there is a fault in the connected device Presetting a Current Limit Value CC In many cases it becomes necessary to preset the current limit prior to having the load connected to the supply To accomplish this the following steps should be followed With no load connected to the supply switch on the power Press the OUTPUT 6 button to the ON position to act...

Страница 5: ...witching Operation Frequency 80KHz 120KHz Power Factor 0 68 Efficiency at Maximum Power 84 85 85 Voltmeter Display 4 Digit Ammeter Display 4 Digit Voltmeter Accuracy 1 5 counts 5V 1 5 counts 10V 1 5counts 20V 1 3counts 5V 1 3counts 10V 1 3counts 20V Ammeter Accuracy 1 5 counts 2A 1 5 counts 1A 1 5 counts 0 5A 1 3 counts 2A 1 3 counts 1A 1 3 counts 0 5A LCD Indication CC CV Amp Volt Output ON OFF P...

Отзывы: