OPERATION - AC/DC VOLTAGE MEASUREMENT
•
Select AC voltage or DC voltage range.
•
Insert the red meter plug into the red jack (positive
terminal) and the black meter plug into the black
jack (COM terminal).
•
Touch the test piece with the red and black meter
plugs.
•
Read the measurement value from the LCD.
•
WARNING: When measuring voltage, the maximum
input voltage is 600V (AC/DC). Do not exceed this
limitation, otherwise it may cause an electric shock.
RESISTANCE/CIRCUIT ON-OFF/DIODE/CAPACITANCE
•
Insert the red meter plug into the red jack (positive
terminal) and the black meter plug into the black jack
(COM terminal).
•
Connect the meter plug in parallel to the test piece for
measurement.
•
Read the measurement value from the LCD screen.
•
WARNING: When measuring resistance/on-off/
capacitance/diode range, do not input voltage over DC
60V or AC 30V to avoid injury.
AC/DC CURRENT MEASUREMENT
AC
•
Select AC range (2A~, 20A~, 100A~).
•
Open the clamp head, insert the
electric wire and close the clamp head.
•
Ensure the electric wire is held in the
geometric centre, indicated on the
clamp head and make sure the clamp
heads are closed.
•
Read the measurement data from the
LCD.
DC
•
Press
SELECT
to enter DC range
(2A , 20A , 100A ).
•
Press
ZERO
before measurement to set the reading to zero. If it does not return to
zero after one press, then press it several times until the reading is zero.
Note: As the product is highly sensitive, to ensure correct data measurement, the
orientation of the meter during measurement should be the same as when zeroed.