Recall Setup

The front panel settings can be recalled from one of the four internal memories.

          Press any button of M1 to M4.

          For example, the memory of the panel setting is recalled in M1.

          After you recall M4, rotate the shuttle knob and then M5 is recalled.

          If the memory indicator is lit on the panel of lights, then the current memory is recalled.

          Note: When a setting is recalled the output automatically turns off.

Remote Control

All models can be connected to a computer through interfaces USB/RS232 on the back of the machine and controlled by the 

remote control.

COM setting

Set up the COM port inside the computer according to the following list:

• 

Baud rate: 9600

• 

Parity bit: None

• 

Data bit: 8

• 

Stop bit: 1

• 

Data fow control: None

Functionality Check

• 

Run this query command via the terminal application, such as MTTTY (Multithreaded TTY).

• 

 This should return the idenitifcation information: Manufacturer, model name,  

serial number, TENMA 72-2535 SN:xxxxxxxx Vx.xx

Entering the Remote Control Mode:

• 

Connect the USB.

• 

The power supply will automatically connect. After a normal connection, there will be a beep from the power supply itself.

• 

The panel keys are locked, so the power supply can only rely on the remote control.

Exiting from the Remote Control Mode:

• 

Close the remote control software.

• 

Disconnect the USB from the back.

• 

The power supply disconnects. You will hear a beep, which hints that the remote control mode has been exited.

• 

The power supply automatically comes in the panel control mode.

Series Remote Control Syntax V2.0

Command format: VSET<X>:<NR2>

1. VSET: command header
2. X: output channel
3. : separator

Содержание 72-10480

Страница 1: ...wark com exclusive brands Farnell com exclusive brands Element14 com exclusive brands Digital Control and Programmable DC Power Supply User Manual Part Number 72 2535 72 2540 72 2545 72 2550 72 2925 72 2930 72 2935 72 2940 72 10480 ...

Страница 2: ...semble unless you are qualified as service personnel AC Input AC input voltage 110V 120V 220V 230V 50 60Hz Connect the protective grounding conductor of the AC power cord to an earth ground in order to avoid electrical shock Operation Environment Location Indoor no direct sunlight dust free almost non conductive pollution Relative Humidity 80 Altitude 2000m Temperature 0 to 40 C Storage Environmen...

Страница 3: ...35 4 digit 4 digit Yes 10mV 1mA 72 2540 4 digit 4 digit Yes 10mV 1mA 72 2545 4 digit 4 digit Yes 10mV 1mA 72 2550 4 digit 4 digit Yes 10mV 1mA 72 2925 4 digit 4 digit No 10mV 1mA 72 2930 4 digit 4 digit Yes 10mV 1mA 72 2935 4 digit 4 digit No 10mV 1mA 72 2940 4 digit 4 digit Yes 10mV 1mA Performance Low noise cooling fan controlled by heatsink temperature Compact size light weight Operation Consta...

Страница 4: ... and the OVP indicator flickers Press the OVP key again and the power supply will recover OCP is OCP indicator When overcurrent function is turned on the OCP indicator light turns on C C is the constant current indicator When the power supply is in the mode of constant current the light will be on C V is the constant voltage indicator When the power supply is in the mode of constant voltage the li...

Страница 5: ...nect the AC power cord and select the corresponding AC voltage according to the back label then connect the AC power cord to the socket on the back panel Press the power switch to turn the power on The display initialises showing the model of the machine and then the setting level which is recalled from the last use Press the power switch again to turn the power off ...

Страница 6: ...ront panel key operation The key LED will turn on To unlock press and hold the LOCK key for two seconds Output Setup Panel Operation Connect the load to the front port CH1 Press the Voltage Current key to switch between the voltage adjustment and current adjustment Adjust the voltage and current with the Voltage Current adjustment knob By default the voltage and current knob work in coarse mode In...

Страница 7: ...lowing list Baud rate 9600 Parity bit None Data bit 8 Stop bit 1 Data fow control None Functionality Check Run this query command via the terminal application such as MTTTY Multithreaded TTY This should return the idenitifcation information Manufacturer model name serial number TENMA 72 2535 SN xxxxxxxx Vx xx Entering the Remote Control Mode Connect the USB The power supply will automatically conn...

Страница 8: ...oltage setting Example VSET1 Returns the CH1 voltage setting 5 IOUT X Description Returns the actual output current Example IOUT1 Returns the CH1 output current 6 VOUT X Description Returns the actual output voltage Example VOUT1 Returns the CH1 output voltage 7 BEEP Boolean Description Turns on or off the beep Boolean boolean logic Example BEEP1 Turns on the beep 8 OUT Boolean Description Turns o...

Страница 9: ...ting Boolean 0 OFF 1 ON Example OCP1 Turns on the OCP 14 OVP Boolean Description Turns on the OVP Boolean 0 OFF 1 ON Example OVP1 Turns on the OVP Specifications Note The specifications in the table below have all been tested in temperatures ranging from 25 C down to 5 C and after being warmed up for 20 minutes Part Number 72 10480 72 2535 72 2540 72 2545 72 2550 72 2925 72 2930 72 2935 72 2940 Vo...

Страница 10: ...mber 72 10480 72 2535 72 2540 72 2545 72 2550 72 2925 72 2930 72 2935 72 2940 Setup Accuracy 25 C to 5 C Voltage Current 0 5 20mV 0 5 5mA 0 5 20mV 0 5 10mA 0 5 30mV 0 5 5mA 0 5 20mV 0 5 20mA 0 5 30mV 0 5 10mA Ripple 20 20m Voltage Current 1mVrms 3mArms 2mVrms 3mArms 1mVrms 3mVrms 2mVrms 5mVrms 1mVrms 3mVrms Temperature Coeffcient Voltage Current 150ppm 150ppm 150ppm 150ppm 150ppm 150ppm 150ppm 150...

Отзывы: