FWR/FWT 10
Page
13
Temtrol, Inc
.
®
Manufacturers of ….. Customized Air Handling Units
(F) MAINTENANCE (Con’t)
Fan Wheel/Motor replacement
(1) To replace a fan wheel/motor assembly, first
disconnect power to the FWR/FWT at the main
control panel.
(2) To gain access to the fan / motor cartridge, remove
the safety personnel screen on the motor end only
(if applicable).
(Figure 7)
(3) To remove safety personnel screen:
Loosen and remove all (4) hex screws from the
bolting flange that retain the screen to the fan
cartridge framing.
(Figure 8 a/b)
Always disconnect power to the fan control
panel before maintenance. Follow all
lockout and tag out procedures.
Rotating equipment. Always disconnect
power to the fan motor before
maintenance.
Fan Control
Panel
SAFETY PERSONNEL SCREEN
SAFETY
PERSONNEL
SCREEN
BOLTING
FLANGES
BOLTING FLANGE
DRIVE SIDE VIEW
FWR
FWT
FIGURE 7
FIGURE 8a/b