FMA4X, FMA4P: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

7

 - 

NOTES

: Shaded boxes represent airflow outside the required 300-450 CFM/ton.

1.

Airflow data includes electric heat and filter.

2.

Airflow data is with no return grill. When using a return grill on 18 & 24 sizes, decrease numbers above by approx. 10 CFM. For 30 & 36 sizes, decrease numbers above by approx. 50 CFM

 - 

NOTES

: Shaded boxes represent airflow outside the required 300-450 CFM/ton.

1.

Airflow based upon dry coil at 230V with no electric heat and factory-approved filter. For FMA4X airflow at 208V is approximately the same as 230V because the multi-tap ECM motor is a constant

torque motor. The torque doesn’t drop off at the speeds in which the motor operates.

2.

Airflow is equivalent for front or bottom return configurations.

Table 4 – PSC -Airflow Performance (Standard CFM)

MODELS

BLOWER SPEEDS

EXTERNAL STATIC PRESSURE (IN WC.)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

FMA4P1800AL

High

813

775

731

692

653

609

560

501

424

Med

695

656

620

581

540

498

440

380

-

Low

603

562

525

485

443

393

-

-

-

FMA4P2400AL

High

947

895

847

799

753

704

655

592

530

Med

845

801

759

716

675

626

573

510

-

Low

676

640

602

563

523

499

-

-

-

FMA4P3000AL

High

1367

1312

1252

1192

1131

1063

990

908

821

Med

1211

1165

1114

1065

1016

960

899

833

748

Low

992

952

912

873

828

782

728

656

627

FMA4P3600AL

High

1397

1345

1290

1263

1196

1116

1051

980

907

Med

1298

1252

1198

1147

1094

1037

976

910

842

Low

1149

1105

1056

1008

960

909

856

791

726

Table 5 – ECM - Airflow Performance (Standard CFM)

MODEL SIZE

BLOWER SPEEDS

EXTERNAL STATIC PRESSURE (IN WC.)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

FMA4X1800AL

Tap (5)

913

881

848

818

792

763

731

691

650

Tap (4)

825

787

753

717

682

650

617

580

540

Tap (3)

737

700

663

630

589

550

511

474

436

Tap (2) - Factory

675

632

596

555

521

480

440

399

366

Tap (1)

590

548

499

455

430

368

338

309

263

FMA4X2400AL

Tap (5)

913

881

848

818

792

763

731

691

650

Tap (4) - Factory

825

787

753

717

682

650

617

580

540

Tap (3)

737

700

663

630

589

550

511

474

436

Tap (2)

675

632

596

555

521

480

440

399

366

Tap (1)

590

548

499

455

430

368

338

309

263

FMA4X3000AL

Tap (5)

1362

1325

1266

1238

1197

1159

1119

1080

1040

Tap (4)

1282

1242

1176

1151

1111

1071

1028

975

936

Tap (3)

1267

1225

1143

1120

1078

1036

993

942

897

Tap (2) - Factory

1157

1111

1052

1016

971

929

884

842

802

Tap (1)

1077

1028

965

932

886

850

804

768

732

FMA4X3600AL

Tap (5)

1362

1325

1266

1238

1197

1159

1119

1080

1040

Tap (4) - Factory

1282

1242

1176

1151

1111

1071

1028

975

936

Tap (3)

1267

1225

1143

1120

1078

1036

993

942

897

Tap (2)

1157

1111

1052

1016

971

929

884

842

802

Tap (1)

1077

1028

965

932

886

850

804

768

732

Содержание FMA4X

Страница 1: ...installed in unconditioned space NOTE Nuisance sweating may occur if the unit is installed in a humid location with low airflow Units are designed for upflow applications only Local codes may limit this free air return type unit to installation in single level applications INSTALLATION Check Equipment Unpack unit and move to final location Remove carton taking care not to damage unit Remove protec...

Страница 2: ...into place install refrigerant tubing as follows 1 Route tubing to connection points taking care not to block service access 2 Remove plugs from liquid and vapor lines 3 Braze connections using either silver bearing or non silver bearing brazing material Do not use soft solder materials which melt below 800 F 427 C Consult local code requirements Always flow nitrogen through the system refrigerant...

Страница 3: ...r NOTE Unit is intended for non ducted return air applications Product Data sheet includes a list of accessories including louvered wall panels and return air opening grills If ducted return is used airflow must meet criteria established in the Product Data Local codes may limit this unit to single level applications Design the duct system in accordance with ACCA Manual 0 Design for Residential Wi...

Страница 4: ...sured along low voltage wire use No 16 AWG color coded insulated 35 C minimum wire A13092 Fig 5 Transformer Connections NOTE Before proceeding with electrical connections make certain that voltage frequency and phase correspond to that specified on rating plate Also check to be sure that the service provided by utility is sufficient to handle additional load imposed by this equipment Refer to unit...

Страница 5: ...motor and Time Delay Board TDB For units with ECM motor the off delay is programmed into the motor Follow Table 2 ECM Motor Speed Taps the corresponding blower off delays for each speed tap CONTINUOUS FAN Thermostat closes R to G G energizes and completes circuit to indoor blower motor When G is de energized there is a 90 s blower off delay COOLING MODE Thermostat energizes R to G R to Y and R to ...

Страница 6: ...t metal parts may have sharp edges or burrs Use care and wear appropriate protective clothing safety glasses and gloves when handling parts WARNING ELECTRICAL OPERATION HAZARD Failure to follow this warning could result in personal injury or death Disconnect all power to unit before servicing field wires or removing control package The disconnect when used on access panel does not allow safe servi...

Страница 7: ...92 530 Med 845 801 759 716 675 626 573 510 Low 676 640 602 563 523 499 FMA4P3000AL High 1367 1312 1252 1192 1131 1063 990 908 821 Med 1211 1165 1114 1065 1016 960 899 833 748 Low 992 952 912 873 828 782 728 656 627 FMA4P3600AL High 1397 1345 1290 1263 1196 1116 1051 980 907 Med 1298 1252 1198 1147 1094 1037 976 910 842 Low 1149 1105 1056 1008 960 909 856 791 726 Table 5 ECM Airflow Performance Sta...