IMPORTANT

: Nitrogen can leak out through the hole that the

needle pierced in the plugs. This does not indicate a leaking
coil nor warrant return of the coil.

ENVIRONMENTAL HAZARD

Failure to follow this caution may result in environmental damage.
Federal regulations require that you do not vent refrigerant to the

atmosphere. Recover during system repair or final unit disposal.

CAUTION

!

INTRODUCTION

Use this instruction manual to install EAM4X & WLAM indoor

coils on multipoise furnaces. EAM4X & WLAM models are

enclosed in a casing.

Table 1

COIL INFORMATION

Model Number Tons

Flush to fit

Furnace

width

Coil Connection

Tube Size

inches

inches (mm)

Liquid

Suc-

tion

EAM4X18L14A 1

*

1/2 14

*

3/16 (360)

3/8

5/8

EAM4X19L17A 1

*

1/2 17

*

1/2 (445)

3/8

3/4

EAM4X24L14A

2

14

*

3/16 (360)

3/8

5/8

EAM4X24L17A

2

17

*

1/2 (445)

3/8

5/8

EAM4X25L17A

2

17

*

1/2 (445)

3/8

3/4

EAM4X30L14A 2

*

1/2 14

*

3/16 (360)

3/8

3/4

EAM4X30L17A 2

*

1/2 17

*

1/2 (445)

3/8

3/4

EAM4X36L14A

3

14

*

3/16 (360)

3/8

3/4

EAM4X36L17A

3

17

*

1/2 (445)

3/8

3/4

EAM4X36L21A

3

21 (533)

3/8

3/4

EAM4X37L17A

3

17

*

1/2 (445)

3/8

3/4

EAM4X37L21A

3

21 (533)

3/8

7/8

EAM4X42L21A 3

*

1/2

21 (533)

3/8

7/8

EAM4X42L24A 3

*

1/2 24

*

1/2 (622)

3/8

7/8

EAM4X43L21A 3

*

1/2

21 (533)

3/8

7/8

EAM4X48L17A

4

17

*

1/2 (445)

3/8

7/8

EAM4X48L21A

4

21 (533)

3/8

7/8

EAM4X48L24A

4

24

*

1/2 (622)

3/8

7/8

EAM4X60L21A

5

21 (533)

3/8

7/8

EAM4X61L21A

5

21 (533)

3/8

7/8

EAM4X60L24A

5

24

*

1/2 (622)

3/8

7/8

EAM4X61L24A

5

24

*

1/2 (622)

3/8

7/8

Model Number Tons

Flush to fit

Furnace

width

Coil Connection

Tube Size

inches

WLAM184AA

1

*

1/2 14

*

3/16 (360)

3/8

5/8

WLAM194BA

1

*

1/2 17

*

1/2 (445)

3/8

3/4

WLAM244AA

2

14

*

3/16 (360)

3/8

5/8

WLAM244BA

2

17

*

1/2 (445)

3/8

5/8

WLAM254BA

2

17

*

1/2 (445)

3/8

3/4

WLAM304AA

2

1/2 14

*

3/16 (360)

3/8

3/4

WLAM304BA

2

1/2 17

*

1/2 (445)

3/8

3/4

WLAM364BA

3

17

*

1/2 (445)

3/8

3/4

WLAM374BA

3

17

*

1/2 (445)

3/8

3/4

WLAM374CA

3

21 (533)

3/8

7/8

WLAM424CA

3

1/2

21 (533)

3/8

7/8

WLAM434CA

3

1/2

21 (533)

3/8

7/8

WLAM484CA

4

21 (533)

3/8

7/8

WLAM604CA

5

21 (533)

3/8

7/8

WLAM614CA

5

21 (533)

3/8

7/8

WLAM604DA

5

24

*

1/2 (622)

3/8

7/8

WLAM614DA

5

24

*

1/2 (622)

3/8

7/8

INSTALLATION

INSPECT EQUIPMENT

File claim with shipper if equipment is damaged.

SELECT INSTALLATION

For upflow application follow:

See

 Table 1 

for dimensions. Note instructions for placement of

coil casing on furnace.

Содержание EAM4X Series

Страница 1: ...personal injury Understand the signal words DANGER WARNING CAUTION and NOTE These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and pro...

Страница 2: ... EAM4X36L21A 3 21 533 3 8 3 4 EAM4X37L17A 3 17 1 2 445 3 8 3 4 EAM4X37L21A 3 21 533 3 8 7 8 EAM4X42L21A 3 1 2 21 533 3 8 7 8 EAM4X42L24A 3 1 2 24 1 2 622 3 8 7 8 EAM4X43L21A 3 1 2 21 533 3 8 7 8 EAM4X48L17A 4 17 1 2 445 3 8 7 8 EAM4X48L21A 4 21 533 3 8 7 8 EAM4X48L24A 4 24 1 2 622 3 8 7 8 EAM4X60L21A 5 21 533 3 8 7 8 EAM4X61L21A 5 21 533 3 8 7 8 EAM4X60L24A 5 24 1 2 622 3 8 7 8 EAM4X61L24A 5 24 1 ...

Страница 3: ...rapped around the outside of coil casing and supply duct contact point NOTE Consult the furnace installation instructions for any special requirements when installing the coil to the furnace Horizontal Right Left Installation A170281 Vertical Upflow Downflow Installation A170280 Figure 2 Adapter s Installation When Coil Overhangs Furnace Downflow Coil Installation IMPORTANT Installing A coils rota...

Страница 4: ... and depth of coil cabinet in the direction of drain pan connection Horizontal Right Installation 1 Use field fabricated attachment plates to secure coil to furnace See Figure 4 2 Use self tapping screws to mount attachment plates to coil casing Self Tapping Screws A13065 Figure 4 Horizontal Right Installation 3 Connect furnace snugly against coil casing 4 Use self tapping screws to attach furnace...

Страница 5: ...ing could result in personal injury Wear eye protection Coil is factory charged with 15 psi nitrogen The coil is under pressure and TXV screen is in place behind liquid line plug DO NOT remove liquid line plug first always remove the suction line plug first to depressurize the coil NOTE Factory nitrogen charge may escape past rubber plugs during storage This does not indicate a leaking coil nor wa...

Страница 6: ... a factory installed hard shut off TXV designed only for use with R 410A refrigerant Use only with outdoor units designed for R 410A NOTE ALL TXV S HAVE PRESET SUPERHEAT SETTINGS AND ARE FIELD NON ADJUSTABLE UNIT DAMAGE HAZARD Failure to follow this caution may result in product damage DO NOT BURY MORE THAN 36 IN OF REFRIGERANT TUBING IN GROUND If any section of tubing is buried there must be a 6 ...

Страница 7: ... off if the water in the secondary pan gets too high Condensate Line Trap Sewer Line Air Gap Above Liquid Level A10216 Figure 11 Condensate Drain to Waste Line WASTE LINE CONNECTION If the condensate line is to be connected to a waste sewer line an open trap must be installed ahead of the waste line to prevent escape of sewer gases See Figure 11 CARE AND MAINTENANCE To continue high performance an...

Отзывы: