IMPORTANT
: Nitrogen can leak out through the hole that the
needle pierced in the plugs. This does not indicate a leaking
coil nor warrant return of the coil.
ENVIRONMENTAL HAZARD
Failure to follow this caution may result in environmental damage.
Federal regulations require that you do not vent refrigerant to the
atmosphere. Recover during system repair or final unit disposal.
CAUTION
!
INTRODUCTION
Use this instruction manual to install EAM4X & WLAM indoor
coils on multipoise furnaces. EAM4X & WLAM models are
enclosed in a casing.
Table 1
COIL INFORMATION
Model Number Tons
Flush to fit
Furnace
width
Coil Connection
Tube Size
inches
inches (mm)
Liquid
Suc-
tion
EAM4X18L14A 1
*
1/2 14
*
3/16 (360)
3/8
5/8
EAM4X19L17A 1
*
1/2 17
*
1/2 (445)
3/8
3/4
EAM4X24L14A
2
14
*
3/16 (360)
3/8
5/8
EAM4X24L17A
2
17
*
1/2 (445)
3/8
5/8
EAM4X25L17A
2
17
*
1/2 (445)
3/8
3/4
EAM4X30L14A 2
*
1/2 14
*
3/16 (360)
3/8
3/4
EAM4X30L17A 2
*
1/2 17
*
1/2 (445)
3/8
3/4
EAM4X36L14A
3
14
*
3/16 (360)
3/8
3/4
EAM4X36L17A
3
17
*
1/2 (445)
3/8
3/4
EAM4X36L21A
3
21 (533)
3/8
3/4
EAM4X37L17A
3
17
*
1/2 (445)
3/8
3/4
EAM4X37L21A
3
21 (533)
3/8
7/8
EAM4X42L21A 3
*
1/2
21 (533)
3/8
7/8
EAM4X42L24A 3
*
1/2 24
*
1/2 (622)
3/8
7/8
EAM4X43L21A 3
*
1/2
21 (533)
3/8
7/8
EAM4X48L17A
4
17
*
1/2 (445)
3/8
7/8
EAM4X48L21A
4
21 (533)
3/8
7/8
EAM4X48L24A
4
24
*
1/2 (622)
3/8
7/8
EAM4X60L21A
5
21 (533)
3/8
7/8
EAM4X61L21A
5
21 (533)
3/8
7/8
EAM4X60L24A
5
24
*
1/2 (622)
3/8
7/8
EAM4X61L24A
5
24
*
1/2 (622)
3/8
7/8
Model Number Tons
Flush to fit
Furnace
width
Coil Connection
Tube Size
inches
WLAM184AA
1
*
1/2 14
*
3/16 (360)
3/8
5/8
WLAM194BA
1
*
1/2 17
*
1/2 (445)
3/8
3/4
WLAM244AA
2
14
*
3/16 (360)
3/8
5/8
WLAM244BA
2
17
*
1/2 (445)
3/8
5/8
WLAM254BA
2
17
*
1/2 (445)
3/8
3/4
WLAM304AA
2
−
1/2 14
*
3/16 (360)
3/8
3/4
WLAM304BA
2
−
1/2 17
*
1/2 (445)
3/8
3/4
WLAM364BA
3
17
*
1/2 (445)
3/8
3/4
WLAM374BA
3
17
*
1/2 (445)
3/8
3/4
WLAM374CA
3
21 (533)
3/8
7/8
WLAM424CA
3
−
1/2
21 (533)
3/8
7/8
WLAM434CA
3
−
1/2
21 (533)
3/8
7/8
WLAM484CA
4
21 (533)
3/8
7/8
WLAM604CA
5
21 (533)
3/8
7/8
WLAM614CA
5
21 (533)
3/8
7/8
WLAM604DA
5
24
*
1/2 (622)
3/8
7/8
WLAM614DA
5
24
*
1/2 (622)
3/8
7/8
INSTALLATION
INSPECT EQUIPMENT
File claim with shipper if equipment is damaged.
SELECT INSTALLATION
For upflow application follow:
See
Table 1
for dimensions. Note instructions for placement of
coil casing on furnace.