17
*Note
: Charging starts automatically when the charge conditions have been met: Charging temperature between
0°C and 35°C
(32°F and 95°F) at the start of charging.
11
IDENTIFICATION
Display
Meaning
State of BB-16
Solution
Temperature too low during
charge (Below 0°C)
(Below
32°F)
The fan does not charge but
works on mains power
Place the fan at room temperature
(20°C +/-5)
(68°F +/-5)
Charge time too long
The fan does not charge but
works on mains power
Check LED battery level status and repeat
charge
Charge current too high
The fan does not charge but
works on mains power
Disconnect and reconnect the mains power
Charge current too low
The fan does not charge but
works on mains power
Check battery fuse, disconnect and reconnect
the mains power
Charge voltage too high
The fan does not charge but
works on mains power
Disconnect and reconnect the mains power
Battery temperature too high
to start charging (Over 40°C)
(Over 104°F)*
The fan does not charge but
works on mains power
Place the fan at room temperature
(20°C +/-5)
(68°F +/-5), leave it connected (charging will
start automatically when the battery has reached
the desired temperature)
Battery temperature too low
to start charging (Below 0°C)
(Below 32°F)*
The fan does not charge but
works on mains power
Place the fan at room temperature
(20°C +/-5)
(68°F +/-5) wait 1 hour and retry
Do not unplug
A battery temperature sensor
is out of service
Normal operation fault
display on power-up on
battery
Disconnect and reconnect the battery
Charge current measurement
out of service
The fan does not charge but
works on mains power
Disconnect and reconnect the mains power
Motor current measurement
out of service
Does not work on battery or
mains
Disconnect and reconnect the mains power
Year of manufacture
Place of manufacture
Reference