16
ð
Speed setpoint LED status during battery and AC power supply use:
Note :
Pressing the
button will increase the LED speed setpoint.
Pressing the
button will decrease the LED speed setpoint.
LEDs indicate the selected speed setpoint; you must wait a few seconds to reach the desire speed.
Alarms and warnings tables:
LED Flashing
Display
Meaning
B
B-16
status
Solution
Driver fault
Does not work on battery or
mains power
Restart the fan
Battery temperature too high
during discharge (Over 55°C)
(Over 131°F)
Stops during use and does
not work on battery
Stop use, place the fan at room temperature
(20°C +/-5)
(68°F +/-5) and restart
1 hour
later
Possibility of using it on mains power
Battery temperature too low
during discharge
(Below -20°C)
(Below -4°F)
Stops during use and does
not work on battery
Place the fan in a room above
-20°C
(-4°F) and
wait for the battery temperature to exceed
-20°C
(-4°F)
Possibility of using it on mains power
Motor current consumption
too high
Stops during use and does
not work on battery or mains
power
Possibility to reduce speed
Check for obstructions or debris on the fan
suction grille and no obstacles impeding the air
flow
Supply voltage too high
Does not work on mains
power
Disconnect and reconnect the mains power
Supply voltage too low
Does not work on mains
power
Disconnect and reconnect the mains power
Speed configuration problem
On mains power the fan self-
configures to a non-
optimised speed/does not
work on battery
Contact
TEMPEST.
Temperature too high during
charge (Over 40°C
)
(Over 104°F)
The fan does not charge but
works on mains power
Disconnect the fan. Place the fan at room
temperature
(20°C +/-5)
(68°F +/-5) and
reconnect to restart charge 1 hour later
Vitesse 20%
Vitesse 40%
Vitesse 60%
Vitesse 80%
Vitesse 100%
Arrêt
Содержание 910-1801
Страница 1: ......
Страница 20: ...20 Package leaflet code BB 16 EN 0...