1.Introduction

 

This Charging Station is designed to charge plug-in hybrid electric vehicles (PHEV) and battery electric

 

vehicles (BEV). And most important, it is OCPP compatible with OCPP 1.6J.

 

1.1 Applications

 

 Residential

 

 Private and public parking facilities

 

 Shopping malls and retailers

 

 Workplace

 

Please  read  and  follow  these  safety  warnings  and  operating  instructions  carefully  before  operating  this

 

Charging Station. Failure to follow these instructions may result in serious injury or property damage.

 

2.Important Safety Warnings and Instructions

 

IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE  INSTRUCTIONS.

 

WARNING

 

 

Used when there is a risk of personal injury.

 

WARNING

 

Used when there is a risk of electric shock.

 

CAUTION

 

Used when there is a risk of fire.

 

CAUTION

 

 

Used when there is a risk of damage to the equipment.

 

 Children should be supervised when this product is used around children.

 

 Do not put fingers into the EV connector.

 

  Do not use this product if the EV cable is frayed, has broken insulation, or displays any other indication of

 

damage.

 

  Do not use this product if the enclosure or the EV connector is broken, cracked, open, or show any other

 

indication of damage.

 

 This product should be installed only by a qualified approved technician.

 

  Make sure that the materials used and the installation procedures follow local building codes and safety

 

standards.

 

  The information provided in this manual in no way exempts the user of responsibility to follow all applicable

 

codes or safety standards.

 

  We manufacturer and our partners are not responsible for physical injury, damage to property or equipment

 

caused by the installation of this product.

 

 This document provides instructions for the wall-mounted Level 2 Charging Station and should not be used for

 

any other product. Before installation or use of this product, you should review this manual carefully and consult

 

with a licensed contractor, licensed electrician, or trained installation expert to make sure of compliance with

 

local building codes and safety standards.

 

01

 

Содержание CARdylet CL-CARGADOR-T-22/32-C

Страница 1: ...CARGADOR DE AC OCPP MANUAL DE USUARIO...

Страница 2: ...ctor EV No use este producto si el cable EV est deshilachado tiene aislamiento roto o muestra cualquier otra indicaci n de da o No utilice este producto si la carcasa o el conector EV est roto agrieta...

Страница 3: ...o est correctamente conectado a tierra ADVERTENCIA RIESGO DE DESCARGA EL CTRICA No toque las partes el ctricas vivas Las conexiones incorrectas pueden causar una descarga el ctrica ADVERTENCIA Este eq...

Страница 4: ...3 Caracter sticas y especificaciones 3 1 Vista frontal Versi n cableada Versi n de enchufe 03...

Страница 5: ...rga parpadeo r pido en verde falla parpadeo r pido en rojo Pantalla LCD de 7 22 F a 122 F 30 C a 50 C 95 de humedad relativa sin condensaci n Interfaz de usuario Control Ambiental cable de 5 m Un bot...

Страница 6: ...acitado para garantizar el cumplimiento de las pr cticas locales de construcci n las condiciones clim ticas las normas de seguridad y los c digos estatales y locales 4 2 Instrucciones de puesta a tier...

Страница 7: ...10 con un tornillo de arandela desde el interior de la caja para fijarla al soporte Nota La estaci n de carga debe montarse a una altura suficiente desde el nivel del suelo de modo que la altura de l...

Страница 8: ...i n de cables de alimentaci n trif sicos de 22KW PE 12V AC DC Meter Contactor N TIPO B L1 L2 L3 Figura 4 3 Conexi n de cables de alimentaci n 5 Configuraci n de Ethernet Wi Fi y 4G Selector Funci n Et...

Страница 9: ...enchufe de carga est n da ados comun quese con el proveedor de la estaci n de carga Se sugiere revisar los componentes principales regularmente Verifique mensualmente si el cable de entrada o la carc...

Страница 10: ...azul la estaci n est fuera de l nea Parpadeo lento verde Verde Preparando el inicio de la carga Pase RFID o conecte el conector Carga en proceso Parpadeo r pido verde Verde El estado del LED vuelve a...

Страница 11: ...ia 10 16 20 25 32 Estado del punto de carga Disponible Prepar ndose SuspededEV SuspededEVSE Faulted Corriente de carga en tiempo real Potencia de carga en tiempo real Tiempo de carga Energ a de carga...

Страница 12: ...veh culo p ngase en contacto con el soporte t cnico El indicador de estado no parpadea en verde cuando la estaci n de carga est conectado al veh culo el ctrico 1 Hay un error temporal 2 Espere hasta q...

Страница 13: ...de 3 ann s contre tout default de fabrication Pour valider cette garantie il est essential d avoir la facture d achat EN T E I Guarantees this product for 3 years against any manufacturing defect To...

Страница 14: ...OCPP AC CHARGER USER MANUAL...

Страница 15: ...he EV connector Do not use this product if the EV cable is frayed has broken insulation or displays any other indication of damage Do not use this product if the enclosure or the EV connector is broke...

Страница 16: ...are in doubt as to whether the product is properly grounded WARNING RISK OF ELECTRIC SHOCK Do not touch live electrical parts Incorrect connections may cause electric shock WARNING This equipment is i...

Страница 17: ...3 Features and Specifications 3 1 Front View Cable version Socket version 03...

Страница 18: ...over temperature protection CE MID Certified meter Standby online blue on offline flashing blue prepare slow flashing green charging fast flashing green fault fast flashing red Status Indicators Disp...

Страница 19: ...contractor licensed electrician or trained installation expert to ensure compliance with local building practices climate conditions safety standards and state and local codes 4 2 Grounding Instructio...

Страница 20: ...crew one M6 10 cross round head with washer screw from box inside securing to the bracket Note The Charging Station must be mounted at a sufficient height from grade such that the height of the plug d...

Страница 21: ...ruction for 3 Phase 22KW power wires connection PE 12V AC DC TYPE B meter contactor N L1 L2 L3 Figure 4 3 Power wires connection 5 Ethernet Wi Fi 4G Settings Select Function Ethernet Static Cellular W...

Страница 22: ...or the charging plug is damaged contact the charging station provider It is suggested to check the major components regularly Check monthly whether input wire or shell of the charging socket is damag...

Страница 23: ...the station is offline Preparing start charging Slow flashing green Green Green Swipe RFID or plug in connector Charging in process Fast flashing green LED status returns to slow flashing green when c...

Страница 24: ...harging point state Available Preparing SuspededEV SuspededEVSE Faulted Current Power Time Real time charging current Real time charging power Charging time Energy Charging energy QRCode Some informat...

Страница 25: ...to charge with the portable cord set that came with the vehicle contact Technical Support connected to the EV 1 There is a temporary error 2 Wait until the temporary error is resolved and the Charging...

Страница 26: ...3 ann s contre tout default de fabrication Pour valider cette garantie il est essential d avoir la facture d achat EN T E I Guarantees this product for 3 years against any manufacturing defect To mak...

Страница 27: ...CHARGEUR AC OCPP MANUEL DE L UTILISATEUR...

Страница 28: ...igts dans le connecteur EV N utilisez pas ce produit si le c ble EV est effiloch a une isolation bris e ou pr sente toute autre indication de dommage N utilisez pas ce produit si le bo tier ou le conn...

Страница 29: ...mis la terre AVERTISSEMENT RISQUE DE CHOC LECTRIQUE Ne touchez pas les pi ces lectriques sous tension Des connexions incorrectes peuvent provoquer un choc lectrique AVERTISSEMENT Cet quipement est de...

Страница 30: ...3 Caract ristiques et sp cifications 3 1 Vue de face Version c ble Version prise 03...

Страница 31: ...d humidit relative sans condensation C ble de 5m Un bouton physique prenant en charge le r glage du courant de sortie un bouton d urgence 3 2 Sp cifications Mod les de chargeurs CA Taper Entr e de Not...

Страница 32: ...en agr ou un expert en installation qualifi pour assurer la conformit avec les pratiques de construction locales les conditions climatiques les normes de s curit et les codes nationaux et locaux 4 2 I...

Страница 33: ...c une vis rondelle de la bo te l int rieur de la fixation au support Noter La station de charge doit tre mont e une hauteur suffisante du niveau du sol pour que la hauteur de la station d accueil soit...

Страница 34: ...es fils d alimentation triphas s 22KW P E 12V TYPE B M tre Contacteur AC DC N L1 L2 L3 Figure 4 3 Connexion des fils d alimentation 5 Param tres Ethernet et Wi Fi et 4G S lectionne r Une fonction Ethe...

Страница 35: ...se de charge est endommag contactez le fournisseur de la station de charge Il est sugg r de v rifier r guli rement les principaux composants V rifiez tous les mois si le fil d entr e ou la coque de la...

Страница 36: ...e bleu clignote la station est hors ligne Pr paration du d marrage de la charge Balayez RFID ou branchez le connecteur Chargement en cours L tat de la LED revient au vert clignotant lentement lorsque...

Страница 37: ...10 16 20 25 32 tat du point de charge disponible en pr paration suspenduEV suspededEVSE en panne Courant de charge en temps r el Puissance de charge en temps r el Temps de charge nergie de charge Cert...

Страница 38: ...snesontpasendommag s 3 Inspectez le VE et son r ceptacle pour d tecter tout dommage 4 Essayez de charger avec le cordon portable fourni avec le v hicule contacter l assistance technique 1 Il y a une e...

Страница 39: ...r e de 3 ann s contre tout default de fabrication Pour valider cette garantie il est essential d avoir la facture d achat EN T E I Guarantees this product for 3 years against any manufacturing defect...