EN
KPA-11T
TRMS CLAMP METER
29 / 46
Function
Range
Accuracy (% of r digits)
Frequency
(Auto-ranging)
10 Hz to 100 kHz
± 1 % ± 5 dig.
Input protection: 1000 V AC
Sensitivity:> 20 MV AC
Frequency through test leads when meter is set to AC voltage
Function
Range
Accuracy (% of r digits)
Frequency
(Auto-ranging)
40 Hz to 1 kHz
± 1 % ± 5 dig.
Maximum input: 2000 A CA
Sensitivity:> 150 A
Over rang protection: 600 V rms
Function
Range
Accuracy
(% of r digits)
Resolution
Temperature
-20 °C to 1000 °C
± (2 % + 5 °C)
0,1 °C
-4 °F to 1832 °F
± (3 % + 9 °F)
0,1 °F
Sensor: K type banana
Over rang protection: 600 V rms
Function
Range
Accuracy
(% of r digits)
Resolution
AC current peak
400 A
± (4 % + 5 dig.)
100 mA
2000 A
± (4 % + 5 dig.)
1 A
Frequency behaviour: 50 Hz ~ 60 Hz
Function
Range
Accuracy
(% of r digits)
Resolution
Capacitance
4 nF
± (5 % + 30 dig.)
0,1 nF
40 nF
± (5 % + 20 dig.)
1 nF
400 nF
± (3,5 % + 10 dig.)
10 nF
4
μ
F
± (5 % + 10 dig.)
100 nF
40
μ
F
± (5 % + 10 dig.)
1
μ
F
400
μF
± (5 % + 10 dig.)
10
μ
F
Over rang protection: 600 V rms
Function
Testing condition
Reading
Diode
Forward DCA is approx. 0,5mA, backward volt-
age is approx. 2V
Forward voltage drops of diode
Continuity
Open voltage is approx. 0.5V
Buzzer makes a long sound, while
resistance is less than (60 ± 30
Ω)
Over rang protection: 600 V rms
Function
Range
Accuracy
(% of r digits)
Resolution
Duty cycle
0,1 % to 99,9 %
± (1,2 % + 5 dig.)
0,1 %