Tempco PCM10001 Скачать руководство пользователя страница 1

Part Number Input Voltage

Max. 

Heater

Maximum  Thermocouple

(50/60 Hz)

Amperage Fusing

Wattage

Sensor Input

PCM10001

120VAC

16

20amps

1920

Type J 

PCM10002

240VAC

16

20amps

3840

Type J

PCM10003

120VAC

16

20amps

1920

Type K

PCM10004

240VAC

16

20amps

3840

Type K

Page 1 of 10

TEMPCO

Electric Heater Corporation

607 N. Central Avenue 

Wood Dale, IL 60191-1452  USA 

630.350.2252 

Fax: 630.350.0232

E-mail: [email protected] 

Web: www.tempco.com

Visionary Solutions for Industry

®

Since 1972 — 

ISO 9001 Certified

Temperature Controllers & Sensors 

Heating Elements 

Process Heating Systems

®

®

Instructions for Tempco Control Enclosure PCM10001 through PCM10004

© 2016 Tempco Electric Heater Corporation       (Revision 6/15/2016)

1: TEC-9100 Controller
2: On-Off Switch
3: 1 Amp Control Fuse
4: 20 Amp Main Fuse (240V model has 2)
5: 120V or 240V Power Cord (20A)
6: 120V or 240V Heater Receptacle (20A)
7: Type J or K Thermocouple Jack

WARNINGS

1. Dangerous voltage capable of causing injury or death is present within this enclosure. Power to all

equipment must be disconnected before installation or beginning any troubleshooting procedures.

All wiring and component replacement must be made by qualified personnel only.

2. To minimize the possibility of fire or shock, do not expose this console to rain or excessive moisture.

3. Do not use this enclosure in areas where hazardous conditions exist such as excessive shock, vibration,

dirt, corrosive gases, oil or where explosive gases or vapors are present.

Temperature Controller:

Model TEC-9100, 1/16 DIN, Dual Display with PID Auto-tuning

Main Power Switch:

Located on Front Panel 

4.00"

6.75"

1

4

5

2

3

7

6

20A-FAST

1A-FAST

Содержание PCM10001

Страница 1: ...oller 2 On Off Switch 3 1 Amp Control Fuse 4 20 Amp Main Fuse 240V model has 2 5 120V or 240V Power Cord 20A 6 120V or 240V Heater Receptacle 20A 7 Type J or K Thermocouple Jack WARNINGS 1 Dangerous v...

Страница 2: ...2 of the TEC 9100 which can be used as a cut out in the event of an over setpoint temperature condition This is a deviation contact set to 30 F above the setpoint In the event of an over setpoint tem...

Страница 3: ...Page 3 of 10 1 5 Menu Overview...

Страница 4: ...Page 4 of 10 Parameter Descriptions TEC 9100 Temperature Controller Controller Parameter Descriptions that are not applicable are not shown in the above table...

Страница 5: ...dvanced PID and Fuzzy Logic algorithm to create a very small overshoot and very quick response to the process if it is properly tuned Cool only control ON OFF control P PD control and PID control can...

Страница 6: ...2 will perform the fail ure transfer function as the controller enters failure mode Output 1 failure transfer if activated will perform 1 If output 1 is configured as proportional control PB 0 and BP...

Страница 7: ...lure mode or manual control mode is entered Procedures Auto tuning can be applied either as the process is warming up cold start or when the process has been in a steady state warm start After the aut...

Страница 8: ...Page 8 of 10 Table A 1 Error Codes and Corrective Actions...

Страница 9: ...ty does not apply to damage resulting from transporta tion alteration misuse or abuse RETURNS No product returns can be accepted without a completed Return Material Authorization RMA form TECHNICAL SU...

Страница 10: ...ce the Advantages of our Diverse and Innovative Products Copyright 2015 All Rights Reserved Electric Heating Elements Thermocouples and RTD Assemblies SCR Power Controls Solid State Relays Mechanical...

Отзывы: