Tempatron TT33 Скачать руководство пользователя страница 4

1. To set the delay times (set times) press the       key, the 

SET

 LED will illuminate and the display will show         (parameter acronym) and its 

programmed value.  To change the value press the       key to increase the value shown or the       key to decrease it.  Note: Press the             keys for 
longer than 1 second to increase/decrease the numerical value more quickly.

Through programming the           parameter it is possible to select which set times can be set in this fast mode.  An option also exists which allows the 
setting of the          set time value only using the              keys without pressing the       key in advance (            = 8).  The options for the            parameter 
are as follows:

oF  

No set time can be set with the       short key (if pressed and released the       key has no effect).

1  

Only         set time value can be set with this procedure.

 Only         set time value can be set with this procedure.

3  

         and         set time values can be set with this procedure.

4  

Only         set time value can be set with this procedure.

5  

         and         set time values can be set with this procedure. 

          and         set time values can be set with this procedure.

          ,         and         set time values can be set with this procedure. 

          set time value can be set directly with the              keys.

For example, when the       parameter is set to 

1

 or 

3

, the procedure is as follows:

- Press and release the       key, the display shows         alternated with the         value.
- To change the set time, press the       key to increase the value or the       key to decrease the value.
- If            = 

1

, once the desired value has been set, press the       key to exit the set time programming mode.

- If            = 

3

, pressing and releasing the       key the display shows         alternating with the value.  To change the value use the              keys using the 

same method as for the         value.
- Once the set time(s) have been programmed, press the       key to exit the set time programming mode.  If no key is pressed for over 10 seconds the 
display will automatically return to normal operation.

x       and         can be set within the limits established by parameters            and            and         can be set within the limits estblished by            and           
.          .

Page 4

SET TIME PROGRAMMING (FAST MODE)

PARAMETER SETTING MODE

To access the timer function parameters when passcode protection is disabled, press the       key for 5 seconds, after which the display shows the code 
that identifies the first programmable parameter.  Use the              keys to select the desired parameter then press the       key, the display will then show 
the parameter code, alternated with its value, that can then be changed with the              keys.  Once the desired value has been reached, press the       
key again to store the new value, the display will then return to show the parameter code.  Press the              keys to select any other desired parameters 
and change them using the same method.  To exit the programming mode, press no key for 30 seconds or keep the       key pressed for 2 seconds.  The 
timer display will then return to showing the timing count value.

PARAMETER PROTECTION USING A PASSCODE

The timer has a parameter protection function using a passcode that can be personalised through the         parameter.  To protect the parameters, set the     
x        parameter to your desired passcode number.
When the passcode protection is active, press the       key for 5 seconds after which the display shows      .  Press the       key and the display will show   . 
Using the              keys, enter the programmed passcode number and press the       key again.  If the passcode is correct the timer will display the code of 
the first programmable parameter and it is possible to program the timer as previously described.
The passcode protection can be disabled by setting         = 

oF

.

Notes: 
1. All parameters are configured by default as protected so that by simply setting the         parameter they are all protected by the passcode.
2. If the passcode is lost, switch the timer OFF then ON, pushing the       key during initial test and keeping it pressed for 5 seconds.  All programmable 
parameters are then accessible and parameter         can be set as required. 

INSERT CORRECT

PASSWORD

PARAMETERS

(PROGRAM MODE)

PASSWORD

REQUEST

Содержание TT33

Страница 1: ...TT33 Digital Multifunction Timer User Manual Tempatron Eltime House Hall Road Maldon Essex CM9 4NF UK Telephone 44 0 1621 859500 Email sales tempatron co uk Web www tempatron co uk...

Страница 2: ...corrosive or flammable gases could be present ELECTRICAL Power Supply Voltage 24Vac dc or 100 240Vac Power Consumption Burden 3VA Frequency 50 60Hz Wiring 2mm screw type terminals Data Retention EEPRO...

Страница 3: ...When in programming mode press to increase the setting value and to select parameters In programming mode press together with the key to change the programming level of the parameters Press together...

Страница 4: ...can be set within the limits established by parameters and and can be set within the limits estblished by and Page 4 SET TIME PROGRAMMING FAST MODE PARAMETER SETTING MODE To access the timer function...

Страница 5: ...is requested Enter the value and press the key to confirm The display shows for 2 seconds and then all parameters have been reset to the factory default values It is possible to completely lock the ti...

Страница 6: ...nt CNT 0 1 2 0 0 1 2 3 0 Start Start 0 1 2 0 Start Stop Reset End Reset Stop Reset OUT1 OPERATING MODES Start OUT1 2 Interval The timer starts counting and the output relay OUT1 energises when the Sta...

Страница 7: ...OUT2 5 Start OUT1 Reset OUT2 4 4 OUT2 Operates the same function as OUT1 but in advance by time OUT2 operates exactly the same function as OUT1 but OUT2 operates in advance of OUT1 has the same time r...

Страница 8: ...STOP 5 Bistable RESET START STOP 6 Bistable START STOP RESET 2 11 OUT1 output operating mode 1 Delay on Energise On Delay 2 Interval 3 Immediate Cycle with Variable On and Off Times 4 Delayed Cycle w...

Отзывы: