TMP

 

Oil Furnaces

 – 

Furnace Manual

 

24

 

 

670-000-004/1010

 

B50098 Rev.B 

ITEM

DESCRIPTION

PART #

1

Complete heat exchanger (item 2, 3, 4, 5 & 6 included)

B30776-01

2

Top heat exchanger

B30542-01

3

Gasket, heat exchanger 

B30517

4

Hexagonal flange nut 3/8-16NC brass

F07O001

5

Combustion chamber

B30518

6

Bottom heat exchanger

B30757

7

Washer 1 7/16 zinc

F06F015

8

Front filter drawer

B30507-01

9

Gasket, burner

B30534

10

Left side panel assembly (item 11 & 12 included)

B30550-04

11

Left side panel insulation

B30571

12

Left filter support

B30566-01

13

Rear panel assembly (item 14 & 15 included)

B30549-01

14

Rear panel insulation

B30572

15

Rear filter support

B30555-01

16

Rear Baffle

B30564

17

Division panel (without item 18)

B30567

18

Blower slide support

B30513

19

Right side panel assembly (item 20 & 21 included)

B30550-03

20

Right side panel insulation

B30571

21

Right filter support

B30566-01

22

Upper front reinforcer

B30556-01

23

Blower door assembly (item 24 included)

B30709-04

24

Door handle

Z99F050

25

Center front panel assembly (item 26 included)

B30703-01

26

Center front panel insulation

B30570

27A

Front right baffle

B30569-01

27B

Front left baffle

B30569-02

28

Bottom front panel assembly (item 29 included)

B30774-01

29

Bottom front panel insulation

B30773

30

Washer 3/8" AA zinc (for burner)

F06F005

31

Hexagonal nut 3/8-16NC (for burner)

F07F024

32

Sight glass

Z99F061

33

5" breech plate

B30459

34

Gasket, breech plate 

B30415-02

35

Burner electrical kit

B30575

36

Corner conduit

B30557

37

Electrical box cover ( without logo )

B40098-01

38

Transformer 120/24 VAC / 40 VA 

L01F009

39

Thermoswitch 160-40F

R02N012

40

Thermoswitch 110-10F

R02N011

41

Relay SPDT 24VAC

L01H009

42

Electrical box (without control)

B30797

43

Terminal strip, 4 positions 

L05F009

44

Blower assembly (45, 47, 50, 51 and 52 included)

B01405-01

45

Blower 100-10T   (housing and wheel included)

B03720-04

46

Belly band assembly (band, legs, nut & bolts included)

B01888

47

Motor assembly 1/3 HP (motor, bell band & legs included)

B01890-01

48

Blower electrical kit

B02916

49

Blower side rails

B30433

50

Seal strip 1 1/2" x 13 1/8"

B01291-01

51

Capacitor 5 MF 

L01I001

52

Capacitor holder

B01024

11

 

Components and replacement parts 

(continued)

 

 

Model TMP furnaces  
 
 
 

 
 
 

Part number

Description

CFB-1-W

Combustible floor base

HFB-1-W

Horizontal floor base

DFVEST-1-W

Counterflow vestibule kit

Optional kit

Содержание TMP Multi-Position

Страница 1: ...e Do not store or use gasoline or other flammable liquids or vapors near this furnace or any other appliance Ventilate house while operating furnace for the first time Odors may be emitted for a brief...

Страница 2: ...of gasoline and oil waste fuel refuse or any other substance in the burner of furnace Installation Do not block flow of combustion or ventilation air to furnace Do not block or obstruct the air openin...

Страница 3: ...rnaces are approved for installation on non combustible floor If a combustible floor is used follow these instructions Horizontal installation on combustible floor Always keep the minimum installation...

Страница 4: ...fireplace When outside air is used Connect each opening directly by ducts to the outdoors or to crawl or attic space that freely connects with outdoors Size per below x Through outside wall or vertic...

Страница 5: ...o avoid Spray cans containing chloro fluorocarbons Permanent wave solutions Chlorinated waxes cleaners Chlorine based swimming pool chemicals Calcium chloride used for thawing Sodium chloride used for...

Страница 6: ...re personal injury death or substantial property damage Duct locations and sizing Verify that the size of the supply and return duct system is sufficient for the application The pressure drop through...

Страница 7: ...In the event that the BVSO repetitively shuts down the oil burner a qualified technician needs to evaluate the cause of this shut down Refer to the figures 3 to 5 at section 6 Wiring Diagrams and deta...

Страница 8: ...me furnace installed with a 4 ton air conditioning evaporator coil Heating mode airflow is still 1 050 CFM Cooling mode airflow use Equation 3 4 CFM 4 x 400 1 600 CFM x The larger number is 1 600 CFM...

Страница 9: ...7 7 6 6 900 14 58 41 31 25 21 19 17 14 12 11 10 9 8 8 7 7 7 1000 16 64 45 34 28 23 20 18 15 13 11 10 9 9 8 8 7 7 1100 16 72 49 38 30 25 22 19 16 14 12 11 10 9 9 8 8 7 1200 16 54 41 33 27 24 21 17 15 1...

Страница 10: ...2 600 12 59 38 28 22 19 16 15 13 700 12 69 44 32 25 21 18 16 15 13 800 14 50 36 29 24 20 18 16 14 900 14 56 41 32 26 22 20 18 15 1000 16 63 45 35 29 24 22 19 17 15 1100 16 69 49 38 31 26 23 21 18 16 1...

Страница 11: ...izontal vent must slope upwards away from the furnace a minimum of inch per foot Connection must be made above bottom of chimney to avoid blockage Vent pipe must not enter chimney far enough to cause...

Страница 12: ...not use Teflon tape as an oil pipe sealant It can cause valves to fail creating hazards Use only flare fittings Do not use compression fittings Failure to comply could result in severe personal injury...

Страница 13: ...TMP Oil Furnaces Furnace Manual 670 000 004 1010 13 Notes...

Страница 14: ...ed wire from BVSO Connect the green ground wire to a cabinet screw Connect power wiring All wiring must conform to x National Electrical Code ANSI NFPA 70 latest edition and any additional national st...

Страница 15: ...TMP Oil Furnaces Furnace Manual 670 000 004 1010 15 6 Wire furnace burner continued PLB Oil Furnaces Furnace Manual Figure 4 Wiring TMP furnaces with direct drive blowers DNS 0888 Rev E...

Страница 16: ...TMP Oil Furnaces Furnace Manual 16 670 000 004 1010 6 Wire furnace burner continued PLB Oil Furnaces Furnace Manual Figure 5 Wiring TMP furnaces with direct drive blowers DNS 0907 Rev C...

Страница 17: ...ture Then adjust burner for correct combustion using combustion test equipment Adjust burner for Draft 0 00 to 0 035 water column draft in furnace combustion chamber For pressure reading replace the s...

Страница 18: ...piping and piping checked for leaks 23 Was burner sealed to furnace and nuts tightened Was burner harness securely plugged in Obtain gas tight seals at burner flange cleanout plates and or flue colle...

Страница 19: ...nozzle and electrode position Check ignition transformer output Reference burner manufacturers instructions Check tube insertion and alignment Check nozzle and electrode position Reference burner manu...

Страница 20: ...on page 21 Failure to comply could result in severe personal injury death or substantial property damage Consult with homeowner to see if there were any Check sequence of operation problems with furna...

Страница 21: ...it in a plastic bag for disposal Wash potentially contaminated clothes separately from other clothing Rinse clothes washer thoroughly NIOSH stated First Aid Eye Irrigate immediately Breathing Fresh ai...

Страница 22: ...ving the electrical wires remove the thermal switch and remove any build up from the thermal switch surface D Do not dent or scratch the surface of the thermal switch If the thermal switch is damaged...

Страница 23: ...TMP Oil Furnaces Furnace Manual 670 000 004 1010 23 11 Components and replacement parts Figure 7 Model TMP furnaces Component locations B50098 Rev A...

Страница 24: ...panel insulation B30570 27A Front right baffle B30569 01 27B Front left baffle B30569 02 28 Bottom front panel assembly item 29 included B30774 01 29 Bottom front panel insulation B30773 30 Washer 3 8...

Страница 25: ...ture rise quantity load ampacity for fuse size weight o F and size amps wiring sizing amps pounds TMP 105 55 70 1 20 X 20 115 60 1 12 2 13 7 15 202 Model Volt Hertz Phase DNS 0908 Rev A BTU h BTU h GP...

Страница 26: ...0 60 Bar 0 75 0 75 CARLIN BURNER EZ 1 Tube insertion 5 3 16 TMP 105 0 4 0 3 Model Input TMP 105 BECKETT BURNER Model AFG 3450 RPM Tube insertion 5 1 8 Input Model Firing rate USGPH Nozzle Delavan Hea...

Страница 27: ...om thermostat 2 If the furnace oil burner should shut down on flame failure the burner primary control will lock out Ask your service technician to show you the correct procedure to reset the primary...

Страница 28: ...TMP Oil Furnaces Furnace Manual X40105 Rev K...

Отзывы: