READ THIS FIRST! 

 

 
 
 
 
 
 
 

 
 
Failure to adhere to the guidelines below can result in severe personal injury, death or substantial property damage.

 
 

Service and maintenance – 

  To  avoid  electric  shock,  disconnect  electrical  supply  before 

performing maintenance. 

  To avoid severe burns, allow furnace to cool before performing 

maintenance. 

  Perform  service  and  maintenance  as  described  in  this  manual 

and the burner manual. 

  Do not attempt to make adjustments to the blower or motor while 

the furnace is in operation. Disconnect power to the furnace and 
be  sure  all  parts  have  stopped  moving  before  attempting 
adjustments or maintenance. 

  The burner must be set up and adjusted using combustion test 

instruments.  Visual  examination  of  the  flame  alone  cannot 
determine combustion performance. 

 
 

Operation - 

  Do not use the furnace as a construction heater. 

  Do  not  operate  any  furnace  if  the  heat  exchanger  is  damaged, 

corroded  or  pitted.  Toxic  flue  products  could  enter  the  air 
stream. 

  Do not jumper, attempt to by-pass or override any limit control. 

  Do not block flow of combustion or ventilation air to furnace. Do 

not block or obstruct the air openings in the furnace casing. 

  Do  not  store  or  use  combustible  materials,  gasoline,  or  other 

flammable liquids or vapors in the furnace area. 

  Do not operate the furnace if the furnace area will be exposed to 

air contaminants as described on page 5. 

  Should overheating occur, do not turn off or disconnect electrical 

supply  to  furnace.  Instead,  shut  off  the  oil  supply  at  a  location 
external to the appliance, if possible. 

  Do not use this furnace if any part has been under water. Call a 

qualified  service  technician  immediately,  to  inspect  the  furnace 
and to replace any part of the furnace, control system or burner 
that was submerged in water. 

  Do  not  operate  furnace  if  temperature  rise  through  heat 

exchanger exceeds 85

o

F. 

 
 
 
 

 
 

  Inspect,  clean  and  replace  (if  necessary)  return  air  filter 

regularly. 

  Do not obstruct return air grills or supply air outlets. 

  Supply  only  #2  fuel  oil  to  the  burner.  Never  attempt  to  use 

gasoline, a mixture of gasoline and oil, waste fuel, refuse or any 
other substance in the burner of furnace. 

 
 
 
 
 

Installation - 

  Do not block flow of combustion or ventilation air to furnace. Do 

not block or obstruct the air openings in the furnace casing. 

  Connect  furnace  only  to  a  functional  vent  system  in  good 

condition.  Place  the  furnace  to  allow  proper  venting,  with  the 
shortest possible venting and minimum number or elbows. 

  Always connect and seal a return air duct to the furnace unless 

the furnace is located in a large space, such as an unpartitioned 
basement.  Route  the  return  air  duct  to  an  adjacent  room  if  no 
return air manifold is used. 

  Install  furnace  maintaining  minimum  clearances  for  service  and 

separation from combustible surfaces described in this manual. 
If  furnace  is  installed  on  a  combustible  floor,  you  must  use  the 
combustible  floor  base  or  provide  the  minimum  clearance  from 
the furnace to the floor as given in this manual. 

  Install,  start-up,  service  and  maintain  burner  per  instructions  in 

this manual and the burner manual. 

  Verify  burner  is  properly  inserted  through  the  combustion 

chamber opening. 

  Furnace  must  be  installed  so  that  burner  and  control  system 

components are protected from dripping, spraying water or rain 
during operation or service. 

  If  installing  an  air  conditioning  evaporator  coil,  install  the  coil 

downstream  of,  or  in  parallel  with,  the  furnace  to  prevent 
condensation  on  the  furnace  heat  exchanger.  If  the  coil  is  in 
parallel,  provide  means  to  prevent  flow  of  chilled  air  into  the 
furnace, including an interlock to prevent simultaneous operation 
of heating and air conditioning. 

 

Apply the following suggestions to prevent unsatisfactory operation of the furnace.

 
 

Installation – 

  Be sure to level the furnace, using a spirit level at the front and 

one  side.  If  the  furnace  is  not  level,  oil  can  drip  into  the 
combustion  chamber  after  burner  cycling,  contaminating  the 
heat exchanger and the burner head. 

  Avoid locating return grills in rooms that may contain undesirable 

odors. 

  Never  locate  a  return  air  grill  closer  than  approximately  20  feet 

from the furnace. 

 
 
 
 

  Locate the furnace near the center of the supply and return duct 

systems. 

  Always check the size of the ducts on a replacement installation, 

particularly if adding air conditioning. 

Содержание TMP Multi-Position

Страница 1: ...e Do not store or use gasoline or other flammable liquids or vapors near this furnace or any other appliance Ventilate house while operating furnace for the first time Odors may be emitted for a brief...

Страница 2: ...of gasoline and oil waste fuel refuse or any other substance in the burner of furnace Installation Do not block flow of combustion or ventilation air to furnace Do not block or obstruct the air openin...

Страница 3: ...rnaces are approved for installation on non combustible floor If a combustible floor is used follow these instructions Horizontal installation on combustible floor Always keep the minimum installation...

Страница 4: ...fireplace When outside air is used Connect each opening directly by ducts to the outdoors or to crawl or attic space that freely connects with outdoors Size per below x Through outside wall or vertic...

Страница 5: ...o avoid Spray cans containing chloro fluorocarbons Permanent wave solutions Chlorinated waxes cleaners Chlorine based swimming pool chemicals Calcium chloride used for thawing Sodium chloride used for...

Страница 6: ...re personal injury death or substantial property damage Duct locations and sizing Verify that the size of the supply and return duct system is sufficient for the application The pressure drop through...

Страница 7: ...In the event that the BVSO repetitively shuts down the oil burner a qualified technician needs to evaluate the cause of this shut down Refer to the figures 3 to 5 at section 6 Wiring Diagrams and deta...

Страница 8: ...me furnace installed with a 4 ton air conditioning evaporator coil Heating mode airflow is still 1 050 CFM Cooling mode airflow use Equation 3 4 CFM 4 x 400 1 600 CFM x The larger number is 1 600 CFM...

Страница 9: ...7 7 6 6 900 14 58 41 31 25 21 19 17 14 12 11 10 9 8 8 7 7 7 1000 16 64 45 34 28 23 20 18 15 13 11 10 9 9 8 8 7 7 1100 16 72 49 38 30 25 22 19 16 14 12 11 10 9 9 8 8 7 1200 16 54 41 33 27 24 21 17 15 1...

Страница 10: ...2 600 12 59 38 28 22 19 16 15 13 700 12 69 44 32 25 21 18 16 15 13 800 14 50 36 29 24 20 18 16 14 900 14 56 41 32 26 22 20 18 15 1000 16 63 45 35 29 24 22 19 17 15 1100 16 69 49 38 31 26 23 21 18 16 1...

Страница 11: ...izontal vent must slope upwards away from the furnace a minimum of inch per foot Connection must be made above bottom of chimney to avoid blockage Vent pipe must not enter chimney far enough to cause...

Страница 12: ...not use Teflon tape as an oil pipe sealant It can cause valves to fail creating hazards Use only flare fittings Do not use compression fittings Failure to comply could result in severe personal injury...

Страница 13: ...TMP Oil Furnaces Furnace Manual 670 000 004 1010 13 Notes...

Страница 14: ...ed wire from BVSO Connect the green ground wire to a cabinet screw Connect power wiring All wiring must conform to x National Electrical Code ANSI NFPA 70 latest edition and any additional national st...

Страница 15: ...TMP Oil Furnaces Furnace Manual 670 000 004 1010 15 6 Wire furnace burner continued PLB Oil Furnaces Furnace Manual Figure 4 Wiring TMP furnaces with direct drive blowers DNS 0888 Rev E...

Страница 16: ...TMP Oil Furnaces Furnace Manual 16 670 000 004 1010 6 Wire furnace burner continued PLB Oil Furnaces Furnace Manual Figure 5 Wiring TMP furnaces with direct drive blowers DNS 0907 Rev C...

Страница 17: ...ture Then adjust burner for correct combustion using combustion test equipment Adjust burner for Draft 0 00 to 0 035 water column draft in furnace combustion chamber For pressure reading replace the s...

Страница 18: ...piping and piping checked for leaks 23 Was burner sealed to furnace and nuts tightened Was burner harness securely plugged in Obtain gas tight seals at burner flange cleanout plates and or flue colle...

Страница 19: ...nozzle and electrode position Check ignition transformer output Reference burner manufacturers instructions Check tube insertion and alignment Check nozzle and electrode position Reference burner manu...

Страница 20: ...on page 21 Failure to comply could result in severe personal injury death or substantial property damage Consult with homeowner to see if there were any Check sequence of operation problems with furna...

Страница 21: ...it in a plastic bag for disposal Wash potentially contaminated clothes separately from other clothing Rinse clothes washer thoroughly NIOSH stated First Aid Eye Irrigate immediately Breathing Fresh ai...

Страница 22: ...ving the electrical wires remove the thermal switch and remove any build up from the thermal switch surface D Do not dent or scratch the surface of the thermal switch If the thermal switch is damaged...

Страница 23: ...TMP Oil Furnaces Furnace Manual 670 000 004 1010 23 11 Components and replacement parts Figure 7 Model TMP furnaces Component locations B50098 Rev A...

Страница 24: ...panel insulation B30570 27A Front right baffle B30569 01 27B Front left baffle B30569 02 28 Bottom front panel assembly item 29 included B30774 01 29 Bottom front panel insulation B30773 30 Washer 3 8...

Страница 25: ...ture rise quantity load ampacity for fuse size weight o F and size amps wiring sizing amps pounds TMP 105 55 70 1 20 X 20 115 60 1 12 2 13 7 15 202 Model Volt Hertz Phase DNS 0908 Rev A BTU h BTU h GP...

Страница 26: ...0 60 Bar 0 75 0 75 CARLIN BURNER EZ 1 Tube insertion 5 3 16 TMP 105 0 4 0 3 Model Input TMP 105 BECKETT BURNER Model AFG 3450 RPM Tube insertion 5 1 8 Input Model Firing rate USGPH Nozzle Delavan Hea...

Страница 27: ...om thermostat 2 If the furnace oil burner should shut down on flame failure the burner primary control will lock out Ask your service technician to show you the correct procedure to reset the primary...

Страница 28: ...TMP Oil Furnaces Furnace Manual X40105 Rev K...

Отзывы: