410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.temcofireplaces.com
CFM Specialty Home Products
Страница 1: ...FORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www m...
Страница 2: ...s 5 Framing 5 Finishing 6 Locating your Electric Fireplace 6 Clearance to Combustibles 6 Hearth 6 Cabinet Installations 6 Main Power Wall Switch Wiring 6 120 Volt Wall Switch Wiring Installation 6 240 Volt Wall Switch Wiring Installation 7 120 240 Volt Wall Mounted Thermostat Wiring 7 Installation Cautions 7 120 Volt Unit Installation 8 120 Volt NH Unit Installation 8 240 Volt Unit Installation 8 ...
Страница 3: ...t surfaces e g beds where openings may become blocked 11 This appliance has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored This fireplace should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung in the area of it 12 Use this appliance only as described in this manual Any other u...
Страница 4: ...mensions Fig 1 Fireplace specifications and framing dimensions Ref TBREF36 TBREF36NH A 40 1016mm B 36 914mm C 36 914mm D 21 533mm E 7 191mm F 19 502mm G 14 356mm H 27 698mm Framing Dimensions J 36 927mm K 41 1041mm L 14 356mm M 37 953mm N 54 1372mm O 27 686mm Electrical Specifications Voltage 120 Volt 120 Volt NH 240 Volt Total Amps 13 Amps 2 Amps 12 9 Amps Total Watts 1550 Watts 240 Watts 3100 Watt...
Страница 5: ...le mantel leg minimum installation Mantel Mantel Leg from Side Ref Leg Depth Ref of Comb Opening F 14 356mm K 14 356mm G 12 305mm L 12 305mm H 10 254mm M 10 254mm I 8 203mm N 8 203mm J 1 38mm O 1 38mm Framing 1 Choose fireplace location 2 Place fireplace into position 3 Frame in the fireplace with a header across the top It is important to allow for finished face when setting the depth of the frame Fo...
Страница 6: ...which allow fast convenient installation of your fireplace against existing walls Main Power Wall Switch Wiring To reduce the risk of fire electrical shock and personal injury before attempting maintenance or service disconnect all power to the fireplace at the main service panel 120 Volt Wall Switch Wiring Installation A qualified electrician must perform any electrical wiring of this appliance For C...
Страница 7: ...ntenance or ser vice to reduce risk of fire electrical shock and personal injury disconnect all power to the fireplace at the main service panel NOTE Wiring of the wall thermostat must be com pleted prior to the installation of the unit Use a single pole thermostat rated for 120 240 Volt operation When installing the wall thermostat make sure to turn the heater control inside fireplace all the way cl...
Страница 8: ... 240 Volt Unit Installation 1 Locate the voltage selection switch under the logset on the left front corner of the unit 2 Check the switch position to ensure it is in the 240 Volt position 3 Loosen the screws securing the junction box cover and remove the cover 4 Remove knockouts in the box cover to use the cable clamp Resetting the Temperature Cutout Switch To reduce the risk of fire electrical sh...
Страница 9: ...Volt 60 Watt E 12 socket base small base chandelier candle type light bulbs These lights are located under the ember bed of the unit Do not exceed 60 Watts per bulb Use of higher rated bulbs may result in fire caus ing property damage personal injury or loss of life NOTE For the sake of convenience you may wish to consider replacing all the light bulbs if one of them burns out 1 Turn OFF the power ...
Страница 10: ...3 20 WHITE 10 BLACK 3 BLACK 4 BLACK BLACK BLACK RED WHITE FP1541 BREF heat wiring 1 05 Component Identification 1 Heater Element 9 Light Bulb 2 Limit Control 175 20 DIF 10 Light Socket w Wiring Assembly 3 Relay Switching 120V 50 60Hz 11 Cable Tie Nylon 6 1 Black 4 Fan Heater Motor 12 Bushing Snap Split 1 5 Thermostat 13 Closed End Splice 2 18 Ga Wire 6 Switch Rocker 14 CFM Wire Req d BREF36 7 Switc...
Страница 11: ...embly 5 Cable Tie Nylon 6 1 Black 6 CFM Wire req d Electrical Wiring Diagram without Heater and Integral Remote Control FP1540 Fig 7 Wiring diagram for models without heat 5 WHITE 2 BLACK L1 N G 3 BLACK 6 WHITE 1 BLACK 7 WHITE 4 BLACK BLACK WHITE BLACK WHITE MOTOR FLAME 3 5 4 2 1 8 WHITE I O 3 2 1 FP1540 BREF no heat wiring 1 05 ...
Страница 12: ... the room Turn the knob clockwise from the OFF position to place the heater into operation The further the knob is rotated clockwise the higher the set point temperature Turn the knob counterclockwise to lower the set point temperature Turn it all the way counterclockwise to turn the heater function OFF Operating Instructions NOTE The device complies with Part 15 of the FCC Rules Operation is subj...
Страница 13: ...ucts reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice TBREF36 TBREF36NH Electric Fireplace TBREF36 TBREF36NH 5 4 3 6 7 2 8 9 11 12 13 15 16 17 4758 BREF parts 1 05 14 20 1 ...
Страница 14: ... 10007639 20 Screen Assembly 7554338 7554338 21 Screen Rod 10007433 10007433 22 One Piece Screen Pull 2 per Fireplace 7554239 7554239 23 Cable Clip 4 per Fireplace 7512135 7512135 Accessories The following accessories for these appliances are available from your local CFM Specialty Home Products distributor NOTE Each accessory comes with a separate in stallation instruction for mounting to the par...
Страница 15: ...SE CFM Specialty Home Products aux présentes nommée la Société garantit votre nouveau foyer électrique Majestic Fireplaces contre tous défauts de fabrication et de matières premières pour une période d un an à compter de la date d installation sujet aux conditions et limitations suivantes 1 Le foyer electrique doit être installé par un entrepreneur de service autorisé et compétent Il doit être ins...
Страница 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www temcofireplaces com CFM Specialty Home Products ...