background image

36

Temco DV1000/1200/1400 Series

76657

Limited Warranty

TEMCO Fireplace Products Direct Vent Gas Fireplaces

This warranty is limited to 

TEMCO Fireplace Products

 

Direct Vent Gas Fireplaces (henceforth, Product) manu-
factured by 

CFM Specialty Home Products

 (hence-

forth, CFM).

ONE YEAR WARRANTY

CFM

 warrants all components of the Product to be free 

of defects in materials and workmanship for a period of 
one year from the date of installation, with the exception 
of the warranty on logs and ember base. If, by the sole 
determination of 

CFM

, any component covered under 

this warranty is found to be defective, 

CFM

 will, at its 

option, repair or replace the defective component at 
no charge and will pay labor cost incurred as specified 
in the current 

CFM

 Labor Allowance Schedule, 71313. 

If 

CFM

 determines replacement or repair is not eco-

nomically practical, 

CFM

 will, at its option, refund the 

purchase price of the Product. Date of installation and 
purchase price must be verified by acceptable proof of 
purchase.
This warranty covers only parts and labor as provided 
above. In no case shall 

CFM

 be responsible for materi-

als, components or construction which are not manu-
factured or supplied by 

CFM

, or the labor necessary to 

install, repair or remove such materials, components or 
construction.

NOTE: 

If allegedly defective  components need to be 

returned by CFM in connection with the above warran-
ties, frieght or postage charges must be prepaid. 

QUALIFICATIONS

For the above warranties to apply:
The Product must be installed by a qualified in-
staller; strictly in accordance with CFM installation 
instructions, and in compliance with local codes 
and ordinances. 

The logs must be placed strictly in ac-

cordance with the arrangement described in the instal-
lation instructions.
The Product must be operated and maintained ac-
cording to the instructions furnished. 

Alteration of the 

Product in any way is prohibited and voids any and 
all warranties. Removal of the data plate alters the 
Product and voids the warranty.

The installer must have completed the installation 
and Startup Checklist, a copy of which must be 
submitted along with proof of purchase, to obtain 
prior approval for warranty repair or replacement 
and to affect a warranty claim. The Checklist is 
found on Pages 20 and 21 of this manual.

The limited warranty applies only to the original owner 
of the Product or the original owner of the dwelling in 
which the Product was installed. Use of any parts other 
than genuine factory provided replacement parts shall 
void this warranty.

Limitations

CFM

 is not responsible for any incidental or consequen-

tial  damages caused by possible defects in the Prod-
uct. The duration of any implied warranty with respect 
to the Product is limited to the duration of the foregoing 
warranties.
CFM is not responsible for any warranty repair (material 
or labor) for defects created by improper field conver-
sions.
Some states and provinces do not allow exclusion of 
incidental or consequential damages or limits on the 
duration of implied warranties, so these limitations may 
not apply to you.

Warranty Fulfillment

Claims require specific agreement and consent 
from CFM Technical Services prior to performing 
any warranty repair or replacement. CFM reserves 
the right to investigate any and all warranty claims.

 

The appliance must not be removed prior to such inves-
tigation other than on direction from 

CFM

.

Please provide the following information when com-
municating with 

CFM

 Technical Services, its Dealers or 

Distributors regarding service under this warranty.

CFM

 reserves the right to decide on the method of 

settlement (if any). This limited warranty is given in lieu 
of any other expressed or implied warranty, and super-
sedes all other 

CFM

 Product warranties.

Model Number: ____________________ 
Serial Number: _____________________
Date of Installation: ____/____/____ 
Purchased From: ___________________

Содержание DV1000N

Страница 1: ...liers instructions If you cannot reach your gas supplier call the fire department DO NOT STORE OR USE GASO LINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTH ER APPLIANCE WARNING Improper installation ad justment alteration service or main tenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer...

Страница 2: ...stible Sidewall Clearance 7 Mantels 7 Surround Material 7 Gas Specifications 8 Gas Inlet and Manifold Pressures 8 Gas Line Installation 8 General Venting Information General Venting 9 General Venting Information Termination Location 10 Termination Clearances 11 Sidewall General Venting Information 12 Flex Venting 12 Sidewall Horizontal Venting 13 Flex Vent Offsets 13 Flex Vent Through the Roof Vert...

Страница 3: ... hours the first time you use it If the op tional fan kit has been installed place the fan switch in the OFF position during this time WARNING When purging the gas line the glass front must be removed 4 Under no circumstances should this fireplace be modified Parts removed for servicing should be replaced prior to operating this fireplace again 5 Installation and any repairs to this fireplace must be p...

Страница 4: ...terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon mon...

Страница 5: ...ss J Box Access Ref DV1000 DV1200 DV1400 A 34 870mm 35 190mm 41 1061mm B 28 721mm 33 838mm 33 838mm0 C 31 791mm 32 827mm 38 984mm D 29 759mm 34 876mm 34 876mm E 16 426mm 21 543mm 21 543mm0 F 5 146mm 6 159mm 6 159mm G 27 699mm 32 813mm 32 813mm H 32 832mm 34 870mm 40 1022mm I 13 333mm 14 362mm 14 362mm J 13 340mm 13 340mm 13 340mm K 1 41mm 1 41mm 1 41mm L 5 130mm 5 143mm 5 143mm M 3 95mm 4 114mm 4 ...

Страница 6: ...le material other than wood flooring the appliance shall be installed on a metal or wood platform 3 Pull out the nail tabs which are located on each side of the fireplace Move the fireplace into position and secure to the floor with screws or nails through the holes provided in the bottom flanges of the side cas ing After checking unit for squareness secure top of fireplace to the framing with screws or...

Страница 7: ...stible mantel meets the minimum height and width require ments for a combustible mantel Surround Material When using materials around the face of the fireplace these materials must be suitable to withstand the tem peratures which they will encounter Also these materi als must not extend out in front of the face of the unit in effect recessing the unit If the material used for surround is not flush w...

Страница 8: ...th shut off is shipped in the con trol valve compartment Using two wrenches tighten the flexible tube at the shut off valve and at the gas control 3 When using a flex connector use only approved fittings When a union is installed provide easy access in it s placement for servicing Refer to gas specification for pressure details and ratings 4 When a vertical section of gas pipe is required for the inst...

Страница 9: ...in the absence of same with CSA B149 1 installation codes in Canada or the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the USA regarding special vent termination clearances These fireplaces are certified for use with four types of venting systems 1 Temco 4 x 7 dia flex vent 2 Temco TDV series 4 x 7 dia rigid vent 3 Simpson Dura Vent GS series 4 x 6 dia vent 4 Security Secure Vent series 4 x...

Страница 10: ...lator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30 cm for 10 000 Btuh 3kW 9 other appliances appliances 10 000 Btuh 3kW and 23 cm for appliances 10 000 100 000 Btuh 30kW 36 91 cm Btuh 3kW and 50 000 Btuh for appliances 100 000 Btuh 30kW 15kW 12 30 cm for a...

Страница 11: ...stible exteriors G Combustible 6 152 mm Noncombustible 2 51 mm F Combustible 6 152 mm Noncombustible 2 51 mm G Balcony with no side wall M Combustible Noncombustible 12 305 mm M Balcony with perpendicular side wall M 24 610 mm P 20 508 mm M F Alcove Applications C D C E V V Combustible Noncombustible V V V E Min 6 152 mm for non vinyl sidewalls Min 12 305 mm for vinyl sidewalls O 8 2 4 m Min O P 5...

Страница 12: ...on arrangement by using chart above and deducting 3 914 mm from the maximum horizontal distance for the second 90 elbow VO584 100 Vent Opening 2 99 djt Vent Opening for Combustible Wall 9 248 mm 10 273 mm 5 149 mm 4 124 mm Fireplace Hearth Framing Detail Opening for Noncombustible Wall Rnd 8 Dia 203 mm Min Fireplace Hearth VO584 100 Fig 15 Locate vent opening on wall 33 838mm Minimum 53 1346mm Max...

Страница 13: ...FTK kit terminal beyond the brick surface If the BEF extension is used measure to the outside surface of the framed wall and add 4 additional inches to the venting length T185 spacer springs 12 3 03 djt Flex Outer Vent Spacer Springs Flex Flue T185 Fig 17 Wrap spacer spring around flex flue pipe overlapping ends CAUTION Care must be taken when tight ening clamps so the flex does not tear at clamp loc...

Страница 14: ... 7 outer pipe on cap Step 4 Slide 7 outer flex over inlet and secure with band clamp 5 Secure vent cap terminal to exterior wall with screw type fasteners as needed Fig 21 6 Connect corrugated side of the extension collar 7 dia into the 7 dia flex pipe Fig 22 Place a small bead of silicone around the collar approximately 1 4 from the leading edge of the corrugation Insert the collar firmly into the fl...

Страница 15: ... 6 1 8m Maximum 35 10 7m Maximum T191 thru the roof installation 12 5 03 djt Roof Attic Insulation Shield 7 178 mm Dia Joists T191 Fig 25 Typical through the roof installation The VSK7 Kit contains Vertical Termination Cap and Storm Collar 4 7 dia x 24 Rigid Pipe unitized 7 dia Roof Support Components 0 12 5 12 Flashing with Storm Collar Tube High Temp Sealant 7 dia Inlet Ext Collar Firestop Hardw...

Страница 16: ...al section and every 6 1 8m on vertical Horizontal sections must maintain a minimum 1 4 rise per linear foot of horizontal run Combustible clearances from any horizontal vent pipe area must be 2 51mm from top of vent and 1 25mm from sides and bottom Clearance to combustibles from vertical pipe surface is 1 25mm Prior to securing each vent component make sure the sections are pushed together firmly ...

Страница 17: ...on of the fireplace its systems and components as certified with the appliance Use of uncertified vent systems or components will void the warranty and may compromise the operation of the fireplace Through the Roof Vertical Venting When the venting penetrates a roof the system must be insalled in accordance with the current CSA B149 1 in stallation code in Canada or the current National Fuel Gas Code ...

Страница 18: ...ill be necessary to replace the last vent section with a shorter vent section In addition you may also measure the distance between the wall and back flanges of the terminal base plate Next trim off the terminal flue and inlet pipes to the dimension measured and reinstall the vent terminal A A A T197 short vent terminal 12 8 03 djt Inlet Pipe Wall Thimble HSQ47 Vent Terminal Cut Lines Push vent term...

Страница 19: ...n Page 17 for Maximum Horizontal Runs T198 Fig 29 Typical TDV Series vent applications Ref DV1000 DV1200 DV1400 A 63 1604 mm 64 1633 mm 71 1808 mm B 44 1135 mm 45 1165 mm 50 1295 mm C 9 237 mm 12 305 mm 14 359 mm D 9 240 mm 9 240 mm 9 240 mm E 37 953 mm 42 1080 mm 42 1080 mm F 48 1226 mm 53 1353 mm 53 1353 mm G 18 476 mm 20 508 mm 20 508 mm H 25 648 mm 30 778 mm 30 778 mm J 36 921 mm 41 1051 mm 41...

Страница 20: ...ickness including furring strips If a Vinyl Siding Standoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 2 51 mm Flat Wall Installation All Units Wall Thickness Vent Length inches mm Required inches mm 5 7 140 178 mm 9 11 6 241 279 mm 152 mm 12 14 9 318 356 mm 229 mm 15 17 12 394 432 mm 305 mm 14 19 11 14 Adj Pipe 368 499 mm 279 372 mm 20 ...

Страница 21: ...l Cap uses 7 4 Flex HFTK Round Hor Term Cap High Wind Includes 7 4 Flex x 3 ft long CDV HSK Round Hor Term Cap uses 7 4 Flex RN47 Vertical Vent Kit Includes 7 4 flex x 10 ft long Firestop Thimble Assy VSK7MH 2 Vertical Vent Kit uses 7 4 Flex VSK7 T199 T204 TDV Series Direct Vent System Installation TDV45S Elbow TDV90 Elbow HSQ47 Horizontal Vent terminal Includes Wall thiumble 75915 SC7 Storm Collar...

Страница 22: ...k 908B 9 Pipe Length Black 907B 12 Pipe Length Galvanized 906 12 Pipe Length Black 906B 24 Pipe Length Galvanized 904 24 Pipe Length Black 904B 36 Pipe Length Galvanized 903 36 Pipe Length Black 903B 48 Pipe Length Galvanized 902 48 Pipe Length Black 902B 11 14 Adjustable Pipe Black 911B 17 24 Adjustable Pipe Black 917B 45 Elbow Galvanized 945 45 Elbow Black 945B 45 Elbow Swivel Galvanized 945G 45...

Страница 23: ...36 Pipe Length Galvanized SV4L36 48 Pipe Length Black SV4LB48 48 Pipe Length Galvanized SV4L48 1 6 Adjustable Pipe Black SV4LBA 1 6 Adjustable Pipe Galvanized SV4LA 1 12 Adjustable Pipe Black SV4LBA12 1 12 Adjustable Pipe Galvanized SV4LA12 1 24 Adjustable Pipe Black SV4LBA24 1 24 Adjustable Pipe Galvanized SV4LA24 45 Elbow Swivel Black SV4EB45 45 Elbow Swivel Galvanized SV4E45 45 Elbow Black SV4E...

Страница 24: ...louvre installation Glass Cleaning It will be necessary to clean the glass periodically Dur ing start up condensation which is normal forms on the inside of the glass and causes dust lint etc to cling to the glass surface Also initial paint curing can de posit a slight film on the glass In some geographic ar eas a white film may be deposited on the glass due to combustion of some of the constituents...

Страница 25: ...oves on the center log The two outside twigs provided on the DV1400 models rest on top of the ends of the grate They are located and supported by the wire formed brackets extending up from the firebox base Fig 35 6 Place rock wool loosely along top edge of ember retainer along entire length of ported area of front burner Use individual pieces of rock wool about the size of a quarter Rock wool shoul...

Страница 26: ... switch and electronic speed control is supplied loose to allow mounting in a conveniently located wall mounted electrical box 2 Wire speed control into black hot side of 120V 60Hz line as shown in blower wiring diagram M White Black T173 blower wiring 11 14 03 djt G Green 120 Volt Speed Control Switch Temperature Sensor Fan T173 Fig 36 Fan wiring diagram CAUTION Should this fan require servic ing...

Страница 27: ...ngs The main gas valve may be adjusted anywhere be tween high and low to give the desired combination of flame aesthetics and heat output H I L O T155 PS24 hi lo knob 11 10 03 djt Turn knob clockwise to increase flame Turn knob counterclockwise to decrease flame Fig 38 Flame adjustment knob Fan Operation The fan operates automatically turn the knob on the speed control to adjust to the desired spee...

Страница 28: ...manually When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a ...

Страница 29: ... magnet 30 seconds or less Re light pilot Pilot will not hold Wrong inlet pressure With the main burner functioning adjust the inlet pressure regulator to supply gas to the appliance within design parameters of the appliance manufac turer Typically 7 NG 11 LPG Pilot adjustment screw not After the pilot has been lit for approximately three properly adjusted minutes and only the thermo generator wir...

Страница 30: ... replace the valve E If closed circuit mv reading is the same as the open circuit reading the coil is electrically open Replace the valve Defective Safety Magnet Verify operation of safety magnet in the following Millivolt system manner A Remove all wires from the terminals of the main operator B Measure the electrical voltage between the term inals TPTH and TP If the voltage is above 110mV and th...

Страница 31: ...TH and TH connections and reconnect the thermostat wires to the same terminals Take the closed circuit voltage as described in the previous step If the mv reading drops below 150mvm excessive resistance exists in the thermostat circuit and must be isolated and eliminated Thermostat wall switch Defective wall switch Repeat the above troubleshooting items covered will not cycle mian under Defective ...

Страница 32: ...ude When installing this fireplace at an elevation between 0 and 2000 feet 0 610m in the USA and 0 and 4500 feet 0 1370m in Canada the input rating does not need to be reduced When installing this fireplace at an elevation above 2 000 feet in the United States it may be necessary to decrease the input rating by changing the existing burn er orifice to a smaller size Input should be reduced four perce...

Страница 33: ...d allowing access to the burn er area use a vacuum cleaner to carefully remove dust and loose particles from the base logs and from around the burners Gloves are recommended to prevent the ceramic fibers that compose the logs from pricking your skin If the skin is pricked wash gently with soap and water Use extreme caution in cleaning around the pilot The pilot should not be moved or altered from t...

Страница 34: ...22 000 10 0 w c 54 DMS Conversion Kits Change Natural Change Propane Model to Propane to Natural DV1000N B32ACLP DV1000P B32ACNG DV1200N B36ACLP DV1200P B32ACNG DV1400N B42ACLP DV1400P B42ACNG Air Shutter Settings Opening Opening Model A inches A mm DV1000N 1 8 3 2 mm DV1000P 1 8 3 2 mm DV1200N 1 8 3 2 mm DV1200P 3 16 4 7mm DV1400N 1 8 3 2mm DV1400P 1 4 6 3mm IMPORTANT Always check for gas leaks w...

Страница 35: ...069 PCOB069 12 Thermocouple PCOA075 PCOA075 PCOA075 13 Thermopile Pilot Generator PCOB021 PCOB021 PCOB021 14 Grate Assembly 76485 76485 76760 15 Rock Wool Bag 76675 76675 76675 16 Black Anodized Aluminum Grille Panels GBL1000 GBL5200 GBL7400 17 Gold Colored Anodized Aluminum Grille Panels GPB1000 GPB5200 GPB7400 18 Platinum Colored Anodized Aluminum Grille Panels PGT1000 GPT5200 GPT7400 19 Black P...

Страница 36: ...rnished Alteration of the Product in any way is prohibited and voids any and all warranties Removal of the data plate alters the Product and voids the warranty The installer must have completed the installation and Startup Checklist a copy of which must be submitted along with proof of purchase to obtain prior approval for warranty repair or replacement and to affect a warranty claim The Checklist...

Страница 37: ...adequate for input rating BTU s per hour of fireplace per National Fuel Gas Code NFPA54 in the case of USA installations or Installation Code CAN 1 149 in the case of Canadian installations Make following checks Gas line integrity at supply line connection Glass front panel position Correct gas pressure Inlet Pressure __________ inches w c Manifold Pressure __________ inchesw c Piezo ignitor functi...

Страница 38: ...quate for input rating BTU s per hour of fireplace per National Fuel Gas Code NFPA54 in the case of USA installations or Installation Code CAN 1 149 in the case of Canadian installations Make following checks Gas line integrity at supply line connection Glass front panel position Correct gas pressure Inlet Pressure __________ inches WC Manifold Pressure __________ inchesWC Piezo ignitor function mi...

Страница 39: ...line To register your warranty please provide the information indicated on this form and mail it to TEMCO Fireplace Products Attn Warranty Registration 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 Model ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper installatio...

Страница 40: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation ...

Отзывы: