background image

STEP 6.  FRAMING CEILING AND ROOF OPENING
SEE FIGURE 17 FOR INSTRUCTIONS IF THE FLUE-PIPE
WILL BE OFFSET BELOW THE FIRST CEILING LEVEL.

If you are not using elbows in this installation frame, the
ceiling and roof openings are directly above one another in
the locations you chose in the Planning Ahead section of
this manual. The flue should go straight up to the chimney
termination. Firestops must be used at each ceiling level. A
firestop is not required at the roof line. The roof framing
must be 2 x 6's or 2 x 4's and must be securely nailed be-
cause the chimney termination and flashing are anchored to
this construction and must withstand heavy loads. The
opening in the ceiling should be square. Use the nail you
previously put in the ceiling as the center of the square. See
below for framing alternative detail. Repeat this procedure

to cut and frame an opening in each ceiling level.
STEP 7. INSTALLING FIRESTOP SPACER
Install a firestop at each ceiling level. The angles on the
firestop are to maintain clearances. Nail the firestop to the
joist and headers around the ceiling opening. No firestop is
to be used at the roof level. The firestop should be installed
from the underside of the ceiling, (see figure 11), except at
the attic level where it should be installed on top at the fram-
ing members, (see figure 12).  A MINIMUM OF 1" AIR
SPACE CLEARANCE MUST BE MAINTAINED FROM THE
CHIMNEY PIPE TO ALL COMBUSTIBLES.
When the chimney penetrates the ceiling at a 90° angle, use
firestop spacer 8204F-1, 14 1/2" x 14 1/2" framed opening.

When the chimney penetrates the ceiling at a 30° angle, use
firestop spacer 8230F-1, 14 1/2" x 22" framed opening.

INSTALLING THE CHIMNEY

Double Wall Chimney pipe has two sections: the inner and
the outer sections.  It is very important that both sections be
installed for each length of chimney used in the system.

STEP 8.
Insert the inner (8") pipe with the male end pointing DOWN
into the inner collar. The inner flue section fits inside the
inner collar. Push the pipe until it bottoms and the snap
locks engage. Check each joint to ensure that the sections
are securely locked together.

STEP 9.
Slip the outer (12") pipe with the male end UP over the other
pipe and over the outer collar. The outer flue section fits on
the outside of the outer flue collar. Push the pipe until it
bottoms and the snap locks engage. Screws may be used
only in the outer pipe for additional support if desired.

STEP 10.
Continue this process of adding chimney pipe sections on
top of each other until the pipe penetrates the roof opening
enough to allow you to install the flashing and storm collar.
Chimney sections must be supported by either guy wires or
3/4" conduit flattened on the ends when the chimney ex-
tends 6' or more above the roof.  The chimney may be ex-
tended to a maximum of 12' above the roof.  A flue support
must be used when the system is 35' or higher.

Figure 8

Figure 9

Figure 11

Figure 12

ROOF CUT TO NEAREST 1/8" ABOVE

Roof Framing Lumber

Pitch

2 x 4

2 x 6

2 x 8

2 x 10

2 x 12

0/12

14 x 14

14 x 14

14 x 14

14 x 14

14 x 14

1/12

12 x 14 1/2

14 x 14 5/8

14 x 14 3/4

14 x 14 7/8

14 x 15 1/8

2/12

14 x 15

14 x 15 1/4

14 x 15 1/2

14 x 15 3/4

14 x 16 1/4

3/12

14 x 15 1/2

14 x 16

14 x 16 1/4

14 x 16 3/4

14 x 17 1/2

4/12

14 x 16 1/4

14 x 16 7/8

14 x 17 1/4

14 x 17 7/8

14 x 18 3/4

5/12

14 x 17

14 x 17 1/4

14 x 17 5/8

14 x 18 1/8

14 x 19 1/4

6/12

14 x 17 7/8

14 x 18 7/8

14 x 19 3/8

14 x 20 3/8

14 x 21 3/4

7/12

14 x 18 3/4

14 x 19 5/8

14 x 20 1/2

14 x 21 5/8

14 x 23 1/4

8/12

14 x 19 3/4

14 x 21

14 x 21 3/4

14 x 23

14 x 24 7/8

9/12

14 x 20 3/4

14 x 22 1/4

14 x 23

14 x 24 1/2

14 x 26 1/2

10/12

14 x 21 3/4

14 x 23 1/2

14 x 24 3/8

14 x 26

14 x 28 1/4

11/12

14 x 23

14 x 24 3/4

14 x 25 3/4

14 x 27 1/2

14 x 30

12/12

14 x 24 1/8

14 x 26 1/8

14 x 27 1/8

14 x 28 1/8

14 x 31 7/8

Figure 10

Содержание A36F-3

Страница 1: ...irculating Fireplace FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified installer Do not attempt to install this fireplace yourself If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or...

Страница 2: ... suggested that you wear work gloves and safety glasses to protect your hands and eyes when installing your fireplace NOTE Authorities having jurisdiction i e building inspec tors fire marshals etc should be consulted before instal lation to determine the need to obtain a permit All models are listed for use in residential construction in the United States with a TEMCO double wall 8 diameter air c...

Страница 3: ...e fireplaces 11 The barometric damper on the Combustion Air Kit al lows air to be drawn from above below or behind the fireplace but air must never be drawn from the attic or garage spaces Refer to the air kit installation manual for complete installation and use information 12 Check your local building code to determine if grounding is required and what procedure should be fol lowed Grounding is ...

Страница 4: ...E INSTALLED ON CARPET OR VINYL Figure 1 Figure 2 Fireplace and Framing Dimensions A B C D E F G H I J K L M N O P Q R S T TFC36 A36F 36 38 1 2 35 37 3 4 7 31 1 4 2 12 1 8 8 5 8 15 1 2 9 21 38 3 4 38 22 8 7 8 46 65 32 1 2 14 3 8 TLC36 A36L 36 38 1 2 35 37 3 4 7 31 1 4 2 12 1 8 8 5 8 15 1 2 9 21 38 3 4 38 22 8 7 8 46 65 32 1 2 14 3 8 TFC39 A39L 39 41 9 16 39 41 1 2 8 33 3 17 9 3 4 18 10 1 2 22 41 13...

Страница 5: ...f joists and rafters will simplify the installation and reduce the cost The structural integrity of a home s floor walls ceiling and roof must be maintained It is not recommended to cut roof trusses CHIMNEY OUTLET Thought should be given to the proposed location of the chimney outlet on the roof Objects such as trees adjacent buildings or embankments that are too close to the chimney can create ai...

Страница 6: ... have a total thermal resis tance R factor equal to or greater than 80 for floor level hearth extensions or 1 20 for raised hearth extensions and be a minimum size as shown in the table on page 5 Choose the desired materials and obtain the K value at 75 mean temperature The C value and the R value may be calculated with the following formulas K Thermal conductivity K BTUs ins hrs ft 2 0 F T thickn...

Страница 7: ...ight The nailing flanges on the side of the firebox were designed to allow the installation of wallboard or plywood flush with the face of the firebox STEP 2 HEARTH SAFETY STRIP A Hearth Safety Strip must be installed under the fireplace when the fireplace is installed on a combustible floor This strip must be positioned on the floor to extend 2 under the fireplace 2 under hearth extension and 6 o...

Страница 8: ...h length of chimney used in the system STEP 8 Insert the inner 8 pipe with the male end pointing DOWN into the inner collar The inner flue section fits inside the inner collar Push the pipe until it bottoms and the snap locks engage Check each joint to ensure that the sections are securely locked together STEP 9 Slip the outer 12 pipe with the male end UP over the other pipe and over the outer col...

Страница 9: ...he chimney sections Minimum system height without elbows 12 6 with two elbows 13 6 with four elbows 21 Maximum height 60 Four 30 elbows maximum per system Lineal Gain Chart Model Lineal Gain 36 fireplaces 37 3 4 39 42 fireplaces 41 1 2 8212D Chimney 10 3 4 8218D Chimney 16 3 4 8224D Chimney 22 3 4 8236D Chimney 34 3 4 3248D Chimney 46 3 4 8232E Elbow set 14 5 8 8204S Flue Support 3 8203D Round ter...

Страница 10: ...2 section 9 1 4 58 7 8 One 18 section 12 1 4 64 Two 12 sections 14 5 8 68 1 4 One 12 and one 18 section 17 5 8 73 1 4 Add to Add to Two 18 sections 20 5 8 78 5 8 Components Dimension X Dimension R One 36 section 21 1 4 79 5 8 12 section 55 93 One 12 and one 36 section 26 5 8 88 7 8 18 section 83 14 1 2 One 48 section 27 1 4 90 36 section 17 3 8 30 One 18 and one 36 section 29 5 8 94 48 section 23 ...

Страница 11: ...A metal cover made by a local sheet metal shop is re quired to complete a chase installation This cover be comes a flashing that prevents water from entering the chase The chase cover should be sealed at the corners A minimum 1 high collar is required at the point where the chimney pipe or slip section will penetrate the chase cover It requires 12 5 8 diameter collar for 36 models 13 5 8 for 39 an...

Страница 12: ...n avoid future cold air problems The time taken to install the firebox correctly is well worthwhile The following steps are recommended to stop potential cold air problems INSULATION OF THE FIREPLACE ENCLOSURE When in a chase or on an outside wall the fireplace enclo sure should be insulated like any other outside wall Insula tion should be installed on the outside walls and the wall above the fir...

Страница 13: ...me ceilings 0 to 30 The firestop thimble is designed to eliminate the need to cut trusses when installing the 8 chimney between stan dard mobile home roof trusses fabricated on 16 centers Locate and mark the center of the chimney on the mobile home ceiling Cut a 14 1 2 square in the ceiling Position the firestop thimble with the flanges up and with the cylin drical portion extending up into the ho...

Страница 14: ...rature adhesive or mortar when anchoring brick stone or tile to the face of the fireplace Check to see whether man made brick and stone are made of non combustible materials before using them on the face of the fireplace Some of these prod ucts contain combustible materials Combustible wall cov erings such as paneling or wallboard may not overlap the black face of the fireplace The space between t...

Страница 15: ...MANTEL PROJECTION Mantel legs may project along the radiation line as illustrated A B 6 min 2 5 8 7 min 3 8 min 3 1 2 10 min 4 3 8 12 min 5 1 4 Figure 26 Figure 27 Hearth Installa ...

Страница 16: ...AT TER RESULTING IN PROPERTY DAMAGE AND OR PER SONAL INJURY TEMCO DOES NOT WARRANT THE GLASS AND IS NOT RESPONSIBLE FOR CONSEQUEN TIAL PROPERTY DAMAGE AS STATED IN THE SEPA RATE GLASS DOOR WARRANTY 13 Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the r...

Страница 17: ... 1A62222 5 Refractory retainer right side 1 2B70358 2B70358 2B68316 6 Refractory retainer left side 1 2B70358 2B70358 2B68339 7 Refractory retainer front 1 2C68372 8 Screws for refractory retainers 2 1A68188 1A68188 1A68188 9 Right side refractory 1 2D70355 2D70355 2D68337 10 Left side refractory 1 2D70355 2D70355 2D68338 11 Back refractory 1 2D70357 2D70425 2D66993 12 Bottom refractory 1 2D70354 ...