Tema Telecomunicazioni AA-10 Скачать руководство пользователя страница 9

TEMA TELECOMUNICAZIONI SRL

                                         

Doorphone PBX interface AA-10

 

MAS-AA10-REV05EN 

 

 

 Page 9 of 12 

 

6.  PARTS COMPRISING THE SYSTEM (PACKING LIST) 

 
AA-10 is shipped with a DIN rail segment, two screws and this manual. 
 

7.  TECHNICAL SPECIFICATIONS 

 

Power 

12V

AC

 or 18V

DC

  

Current consumption 

180 mA 

Operating temperature 

0

˚

C-45

˚

Humidity 

95% non-condensing 

Mount 

DIN rail 

Size and weight 

H90 x W52 x D60 mm, 180 gr 

Doorlock relay max load 
 

24V

DC

 / 5A – (250V

AC

 / 6A relay specification) 

WARNING: this relay has a pole in common with 
screw terminal 5, it cannot drive loads connected to 
powerline 

Auxiliary relay max load 

24V

DC

 / 1A – (120V

AC

 / 1A relay specification) 

WARNING: they cannot drive powerline loads 

Phone line connection 

Twisted wire for connection to PBX trunk 

Line impedance, voltage and current 

600 

Ω

, 48 V

DC

 when idle, 25mA max. off-hook 

Max line loop resistance 

800 

Ω

 

Ring generator 

65 V

RMS

, 25Hz on open circuit, 

40 V

RMS

, 25Hz on 3 REN (400 

Ω

 

8.  OPERATING COMMANDS 

 
These  are  the  commands  available  when  the  device  calls  the  operator.  It  is  always  possible  to 
reach the device (from a PBX extension) to issue the commands or configure AA-10. 
The commands are available 

only after the call is answered

 
To enter command mode: 

- reach AA-10 from the PBX 

 

- dial “1” (only for “normal” mode, not for “autoconnect”) 

 

Digit 

Command 

Description 

Activate door lock relay 

Opens the electric lock of any door or gate that requires 
to close a contact for a short time 

Activate AUX1 relay 

Used for example to turn on lights 

Activate AUX2 relay 

Used for example to turn on lights 

De-activate AUX1 relay 

Only in steady mode 

De-activate AUX2 relay 

Only in steady mode 

De-activate AUX1 and AUX2 relay 

Only in steady mode 

## 

Enter programming mode 

Described in the following 

 
If a digit is dialed other than those listed, three high-pitch tones are emitted. 
 

8.1. 

Front panel LEDs 

 

Green  LED “AL” 

Lit when the device is powered 

 

Red  

LED “R” 

Reports the device status 

Off

 

AA-10 idle 

Blinking 

AA-10 active, waiting for DTMF commands / Ring generator 

Steady on 

AA-10 active, conversation with doorphone or programming 

 

Содержание AA-10

Страница 1: ...terials that they have not supplied 2 The device has been carefully manufactured and tested In any case the product is not recommended for use in situations in which incorrect operating may result in damage to persons and or property 3 We recommend that you carefully read all this manual before starting to use the device 4 Do not expose the device to sunlight and protect it from sources of heat du...

Страница 2: ...tachment TELECOMUNICAZIONE requirements for pan European approval for connection to the analogue Public Switched Telephone Networks PSTNs of TE excluding TE supporting the voice telephony service in which network addressing if provided is by means of Dual Tone Multi Frequency DTMF signalling Inoltre il prodotto sopra menzionato soddisfa i requisiti essenziali delle seguenti direttive Direttiva LVD...

Страница 3: ... recycling techniques Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants and other hazardous substances into the waste stream while recycling leads to reduction of disposal of waste and the negative impacts on environment and human health That is priority is given to reuse of WEEE in its components subassemblies and consumables As the final holder the user ...

Страница 4: ...n the meanwhile it beeps every 2 seconds In the normal mode the operator must dial 1 to activate the communication with the external doorphone Once the voice connection is established the operator can activate the open door relay dialing 2 Hanging up AA 10 returns idle and ready for a new access request It is also possible to connect with the external doorphone dialing the suitable digits dependen...

Страница 5: ...crew terminals 16 17 are for connecting the PBX trunk line 4 2 Volume adjustment The two trimmers on the top side see picture below adjust the microphone and speaker volume Mic external doorphone microphone sensitivity Alt external doorphone speaker sensitivity Before proceeding to the installation it is advisable to set the trimmers to half range Then adjust the Mic trimmer to obtain a good liste...

Страница 6: ...LLATION 5 1 Connection examples In the following examples of connection with some brands of doorphones are presented Find your model and connect it as indicated AA 10 Door Phone Interface Trunk Connection to ELVOX doorphone Connection to URMET doorphone AA 10 Door Phone Interface Trunk Line Line ...

Страница 7: ...MUNICAZIONI SRL Doorphone PBX interface AA 10 MAS AA10 REV05EN Page 7 of 12 AA 10 Door Phone Interface Trunk AA 10 Door Phone Interface Trunk Connection to TERRANEO doorphone Connection to BPT doorphone Line Line ...

Страница 8: ...ace AA 10 MAS AA10 REV05EN Page 8 of 12 Connection to FARFISA doorphone Connection to COMELIT doorphone AA 11 Door Phone Interface Extension AA 11 Door Phone Interface Extension Please note the additional resistor Please note the additional resistor ...

Страница 9: ...NG COMMANDS These are the commands available when the device calls the operator It is always possible to reach the device from a PBX extension to issue the commands or configure AA 10 The commands are available only after the call is answered To enter command mode reach AA 10 from the PBX dial 1 only for normal mode not for autoconnect Digit Command Description 2 Activate door lock relay Opens the...

Страница 10: ...X1 is activated with a pulse or steadily closed until it is commanded to de activate Set n for your needings Range max 1 digit 1 1 pulse 6 n AUX2 relay mode n 1 pulse once n 2 steady Relay AUX2 is activated with a pulse or steadily closed until it is commanded to de activate Set n for your needings Range max 1 digit 1 1 pulse 7 n Relay pulse duration n 1 0 25 sec n 2 0 50 sec n 3 1 00 sec Duration...

Страница 11: ...TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA 10 MAS AA10 REV05EN Page 11 of 12 REMARKS ...

Страница 12: ...TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA 10 MAS AA10 REV05EN Page 12 of 12 REMARKS ...

Отзывы: