TEMA TELECOMUNICAZIONI SRL
Doorphone PBX interface AA-10
MAS-AA10-REV05EN
Page 10 of 12
8.2.
Table of programming parameters
The table below lists all the programming parameters for AA-10.
The parameters are stored in a non-volatile memory and are not lost even in case of loss of power.
To enter programming mode:
“Normal” mode
- reach AA-10 from the PBX
- dial “1 # #”
“Autoconnect” mode
- reach AA-10 from the PBX
- dial “# #”
Digit
Parameter name
Description
Range = allowed values
Default
Your setting
1 n
Ring Frequency
n = 0, Ring 25 Hz
n = 1, Ring 50 Hz
Set the Ring frequency ( 25 or 50 Hz).
Range: max 1 digit
0
(25 Hertz)
2 n
Ring Cadence
n = 0, 1 sec / 4 sec
n = 1, 1 sec / 2 sec
Set the Ring cadence: normal (1 second ring, 4 seconds
pause) or fast (1 second ring, 2 seconds pause).
Range: max 1 digit
0
(1/4 sec)
3 n
Time out for answer
n = 0, 30 sec
n = 1, 45 sec
n = 2, 60 sec
n = 3, 90 sec
Set the max time in seconds during AA-10 waits for
operator answer .
Range: max 1 digit
1
(45 sec)
4 n
Door lock mode
n = 1, pulse once
n = 2, pulses twice
n = 3, pulses 3 times
The door lock relay is activated with one or more
consecutive pulses. Set “n” for your needings.
Range: max 1 digit
2
(2 pulses)
5 n
AUX1 relay mode
n = 1, pulse once
n = 2, steady
Relay AUX1 is activated with a pulse or steadily closed
(until it is commanded to de-activate). Set “n” for your
needings.
Range: max 1 digit
1
(1 pulse)
6 n
AUX2 relay mode
n = 1, pulse once
n = 2, steady
Relay AUX2 is activated with a pulse or steadily closed
(until it is commanded to de-activate). Set “n” for your
needings.
Range: max 1 digit
1
(1 pulse)
7 n
Relay pulse duration
n = 1, 0.25 sec
n = 2, 0.50 sec
n = 3, 1.00 sec
Duration of the pulse (for all relays).
Note: the door-lock relay is always subjected to this
setting, the AUX relays only if programmed in pulse mode.
Range: max 1 digit
1
(0.25 sec)
9 n
Operational mode
n = 1, “Normal”
n = 2, “Autoconnect”
Operational mode settings. In the “normal” mode the
operator must dial “1” to activate the communication with
the external doorphone. Otherwise in “autoconnect” mode
AA-10 will immediately connect the visitor with the
operator (no “1” digit required).
Range: max 1 digit
1
(normal)
8
Reset all values to
the factory default
WARNING:
issue this command only if you want to reset
all values to the factory default, losing your settings.
This command acts without asking any confirmation:
use it with care!
-
-
For example, if you want that the door-lock is activated twice: reach AA-10 from the PBX, dial 1##
to enter programming mode, dial 42 to set the door lock mode parameter, then hang up. After that,
whenever the command 2 is dialed the door-lock relay will be closed twice in succession.