background image

 

10 

FMU126 | 

Wiki

 

Mounting recommendations 

 

Connecting wires  

 

Wires should be connected while the module is not plugged 
in. 

 

Wires should be fastened to stable wires or other non-
moving parts. Any heat emitting and/or moving objects 
should be kept away from the wires. 

 

There should be no exposed wires. If factory isolation was 
removed while connecting the wires, the isolation material 
should be applied. 

 

If the wires are placed in the exterior or in places where they 
can be damaged or exposed to heat, humidity, dirt, etc., 
additional isolation should be applied and the wires should 
not be loose. 

 

Wires cannot be connected to the board computers or 
control units. 
 

 

Connecting power source 

 

Be sure that after the car computer goes to sleep mode, 
power might be still available on the power wires. 
Depending on the car model, this may happen in 5 to 30 
minutes period. 

 

When the module is connected, measure the voltage again 
to make sure it did not decrease. 

 

It is recommended to connect to the main power cable in 
the fuse box. 

 

3 A, 125 V external fuse shall be used. 
 

 

Connecting ignition wire 

 

Be sure to check if it is a real ignition wire i. e. power does 
not disappear after starting the engine. 

 

Check if this is not an ACC wire (when key is in the first 
position, most of the vehicle electronics are available). 

 

Check if power is still available when you turn off any of 
vehicles devices. 

 

Ignition is connected to the ignition relay output. As 
alternative, any other relay, which has power output when 
ignition is on, may be chosen. 
 

 

Connecting ground wire 

 

Ground wire is connected to the vehicle frame or metal 
parts that are fixed to the frame. 

 

If the wire is fixed with the bolt, the loop must be connected 
to the end of the wire. 

 

For better contact scrub paint from the spot where loop is 
going to be connected. 

 

 

Содержание FMU126

Страница 1: ...Quick Manual v1 0 Advanced 3G terminal for DLT project in Thailand FMU126...

Страница 2: ...he battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic char...

Страница 3: ...3 FMU126 Wiki Know your device Figure 1 FMU126 device view...

Страница 4: ...ive through RS232 4 RS232 TX Output for data transmit through RS232 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Open collect...

Страница 5: ...5 FMU126 Wiki Figure 3 FMU126 Wiring scheme Wiring scheme 1 Automotive relay 1 1...

Страница 6: ...in Teltonika Configurator Make sure that SIM card cut off corner is pointing outward from slot SIM slot 1 is closer to PCB SIM slot 2 is the top one 3 Connect battery as shown to device Position the...

Страница 7: ...r installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Con...

Страница 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Страница 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Страница 10: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Страница 11: ...ep mode Blinking fast for a short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characteristics MODULE Name Quectel UC15 T...

Страница 12: ...emperature without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery discharge temperature 20 C to 60 C Batte...

Страница 13: ...nput Voltage threshold DIN 1 7 5 V Input Voltage threshold DIN 2 2 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 150 k Measurement error on 12...

Страница 14: ...ess which is inaccessible to the operator All related devices must meet the requirements of EN 62368 1 standard The device FMU126 is not designed as a navigational device for boats Do not disassemble...

Страница 15: ...before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equipment should not be mixed with general h...

Страница 16: ...uivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODUCTS ARE INTENDED TO BE USED...

Отзывы: