background image

 

   

 

 

 

FMC125 | 

Wiki

 

Quick SMS configuration 

Default configuration has optimal parameters present to ensure 
best performance of track quality and data usage. 

Quickly set up your device by sending this SMS command to it:  

 

Note

: Before SMS text, two space symbols should be inserted. 

GPRS settings: 

 

2001 – APN 

 

 

 – APN username (if there 

2002
are no APN username, empty 
field should be left) 

 

 – APN password (if there 

2003
are no APN password, empty 
field should be left) 

Server settings: 

 

 – Domain  

2004

 

 – Port 

2005

 

 – Data sending protocol 

2006
(0 – TCP, 1 – UDP) 

 
 

Default configuration settings 

Movement and ignition detection: 

 

Vehicle movement will 
be detected by 
accelerometer 

 

Ignition will be detected 
by vehicle power voltage 
between 13,2 – 30 V 

Device makes a record 

On Moving

 if one of these events happen: 

 

300 seconds passes 

 

Vehicle turns 10 degrees 

 

Vehicle drives 100 
meters 

 

Speed difference 
between last coordinate 
and current position is 
greater than 10 km/h  

Device makes a record 

On Stop

 if: 

 

1 hour passes while 
vehicle is stationary 
and ignition is off 

 

 

Records sending to server: 

 

If device has made a 
record it is sent to the 
server every 120 
seconds 

 

 

After successful SMS configuration, FMC125 device will 

synchronize time

 and 

update records

 to 

configured server

Time intervals and default I/O elements can be changed by using 

Teltonika Configurator

 or 

SMS parameters

. 

 

"  setparam 

:APN;

2001

:APN_username;

2002

:APN_password;

2003

:Domain;

2004

:Port;

2005

:0" 

2006

 

Содержание FMC125

Страница 1: ...Quick Manual v1 0 Advanced LTE terminal with GNSS and LTE 3G GSM connectivity RS485 RS232 interfaces and backup battery FMC125...

Страница 2: ...he battery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic char...

Страница 3: ...3 FMC125 Wiki Know your device Figure 1 FMC125 device view...

Страница 4: ...data receive through RS232 4 RS232 TX Output for data transmit through RS232 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Ope...

Страница 5: ...5 FMC125 Wiki Figure 3 FMC125 Wiring scheme Wiring scheme 1 Automotive relay 1...

Страница 6: ...in Teltonika Configurator Make sure that SIM card cut off corner is pointing outward from slot SIM slot 1 is closer to PCB SIM slot 2 is the top one 3 Connect battery as shown to device Position the...

Страница 7: ...er installation window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Co...

Страница 8: ...y 1 Load from device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update f...

Страница 9: ...detected by accelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degree...

Страница 10: ...on the car model this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable...

Страница 11: ...king or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characteristics Module Name Quectel EC21 AU Quectel EC21 EC Teltonika TM2500 Technology LTE CaT1 3G UMTS HSPA 2G GSM...

Страница 12: ...re without battery 40 C to 85 C Operating humidity 5 to 95 non condensing Ingress Protection Rating IP41 Battery charge temperature 0 C to 45 C Battery discharge temperature 20 C to 60 C Battery stora...

Страница 13: ...V Input Voltage threshold DIN1 7 5 V Analog Input Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 150 k Measurement error on 12V Range 1 0 9 Additional error on...

Страница 14: ...ess which is inaccessible to the operator All related devices must meet the requirements of EN 60950 1 standard The device FMC125 is not designed as a navigational device for boats Do not disassemble...

Страница 15: ...is necessary to read the User s Manual before your start using the device Full User s Manual version can be found in our Wiki This sign on the package means that all used electronic and electric equip...

Страница 16: ...product Replaced with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODU...

Отзывы: