Quick Manual v1.4 // FMC00A
10
Telematics
DEFAULT CONFIGURATION SETTINGS
MOVEMENT AND IGNITION DETECTION:
DEVICE MAKES A RECORD ON MOVING
IF ONE OF THESE EVENTS HAPPEN:
SPEED DIFFERENCE
between last coordinate
and current position is
greater than 10 km/h
VEHICLE DRIVES
100 meters
VEHICLE TURNS
10 degrees
PASSES
300 seconds
After successful SMS configuration, FMC00A device will synchronize time and update records to configured server. Time intervals
and default I/O elements can be changed by using
.
1
wiki.teltonika-gps.com/view/Teltonika_Configurator
2
wiki.teltonika-gps.com/view/Template:FMB_Device_Family_Parameter_list
VEHICLE MOVEMENT
will be detected by
accelerometer
DEVICE MAKES A
RECORD ON STOP IF:
1 HOUR PASSES
while vehicle is
stationary and
ignition is off
IGNITION
will be detected by
vehicle power voltage
between 13,2 – 30 V
RECORDS SENDING TO
SERVER:
EVERY 120 SECOND
it is sent to the server
If device has made a
record