![Teltonika FMB900 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/teltonika/fmb900/fmb900_user-manual_1084776016.webp)
16
Figure 4 Driver installation window
You have now installed drivers for FMB900 device successfully.
Table 2 FMB900 pinout description
Pin
Nr.
Pin Name
Description
1
VCC (10
30)V DC (
+
)
Power supply for module. Power supply range (10...30) V DC (
+
)
2
GND(VCC(10
30)V DC)(
-
)
Ground pin. (10
30)V DC (
―
)
3
DIN 1
Digital input, channel 1. DEDICATED FOR IGNITION INPUT
4
AIN 1
Analog input, channel 1. Input range: 0-30V DC
5
OUT 1
Digital output, channel 1. Open collector output. Max.
3,3 A.
3.4
Accessories
Note: Accessories are not included in device package, please order them
separately.
Alarm buttons, door sensors, etc.
Alarm buttons, door sensors, ignition, etc. return two states: high or low voltage. Digital
inputs are used to read this information. Figure below shows how to connect alarm button, door
sensor, etc.