Table 34 Global parameters values
Parameter
ID
Possible Parameter Value
Default Value
Profile Change On Event
100
0/1 (0 – disable, 1 – enable)
0
Prefered records saving
destination
101
0/1 (0 – internal memory, 1 – SDcard)
10
Analog Input 1-2 Type
105
0/1 ( 0 – 10 V, 1 – 30 V)
0
Static Navigation On/Off
107
0/1 (0 – disable, 1 – enable)
1
Records Sorting
108
0/1 ( 0 – from newest, 1 – from oldest)
0
Active Data Link Timeout
109
0 – 259200 (time in seconds)
5
Accelerometer Filter Start Value
112
1 – 10 (time in seconds)
1
Accelerometer Filter Stop Value
113
1 – 255 (time in seconds)
30
Continious Odometer
114
0/1 (0 – disable, 1 – enable)
0
J1708 Enable parameter
115
0/1 (0 – disable, 1 – enable)
0
GNSS Satellite System
116
0/1/2/3/4 (0 – all available, 1 – GPS, 2 –
GLONASS, 3 – GNSS (all available) + SBAS, 4 –
GPS + SBAS)
0
Garmin Ping
117
0/1 (0 – disable, 1 – enable)
0
Garmin Unicode
118
0/1 (0 – disable, 1 – enable)
1
Com1 baudrate
119
0 – 115200
COM1 Mode
120
0-255 (5 - Silent,97 – LLS Mode,98 – LCD Mode,
99 – RFID Mode, 100 – RFID MF7 Mode,
101 – Garmin Mode, 161 – COM TCP Link Mode,
177 – COM TCP Link Mode Binary,
203 – DTO 1731, 204 –SE500, 10-11 – reserved)
0
GNSS TMO For NTP
121
0-300
0
COM2 Baudrate
122
0 – 115200
5
COM2 Mode
124
0 – 255 (5 - Silent, 13 - FM Log, 15 – NMEA,
97 - LLS, 98 - LCD, 99 - RFID, 100 - RFID M7,
101 - Garmin, 161 - COM TCP Link,
177 - COM TCP Link binary)
115200
COM1 Timestamp
151
0/1 (0 – disable, 1 – enable)
0
COM1 CMD ID
152
0 – 255
0
COM2 Timestamp
151
0/1 (0 – disable, 1 – enable)
10
COM2 CMD ID
152
0 – 255
3
Network Ping Timeout
155
0 – 30 (time in minutes)
0
Data saving without time
synchronization
157
0/1 (0 – disable, 1 – enable)
0
Tachograph ignition source
158
1/2/3/4
3
SMS Event number
222-
231
string
„“
RS485 Activate
232
0/1
0
RS485 Baudrate
233
0 – 115200
115200
Содержание FM6320