38
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
1
4294967295
3600000
SMS Data send week time schedule
U32
9.3
Security settings and parameters
SMS User login (ID=252)
User login is used to ensure module security. Used in every SMS that is sent to device.
Example: ba321
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
empty
5 char
string
-
S8[5]
SMS User password (ID=253)
User password is used to ensure module security. Used in every SMS that is sent to device.
Example: ab123
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
Empty
5 char
string
-
S8[5]
Server Number (ID=260)
Value is server GSM number. To this number the SMS with 24 coordinates is sent.
Example: 370XXXXXXXX
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
Empty
16 char
string
-
S8[16]
Authorized Number #1 (ID=261)
Parameters ID=262 to ID=269 have values for 8 more authorized numbers If at least one
number is entered then only those number can send messages to device.
Example: 370XXXXXXXX
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value type
Empty
16 char
string
-
S8[16]