Teltonika FM3200 Скачать руководство пользователя страница 33

 

 

33 

 

setparam #### # 
Sets new value for parameter. ID consists of 4 digits 

 first digit identifies profile, second, third and 

fourth identifies parameter ID as described in Parameter List chapter. In value field a new parameter 
value is entered. 

 

Example: 

setparam 1245 127.0.0.1

 will change configured IP address in profile1 with new value 

 

flush #,#,#,#,#,#,# 
Initiates  all  data  sending  by  GPRS  to  specified  target  server.  Comma  separated  parameters  go  as 
numbered: 

 

1.# - IMEI 

2.# - APN 
3.# - GPRS LOGIN 

4.# - GPRS PASSWORD 

5.# - IP 

6.# - PORT 
7.# - MODE (0-TCP/1-UDP) 

 

Parameters  are  separated  by  comma  (no  spaces  needed). In  case  you  don’t need  to  enter parameter 

(Login/Pass) 

 do not put space, simply put comma and write next parameter. 

 

Example: opa opa flush 353976012555151,banga,,,212.47.99.62,12050,0 

 

Response details 

Description 

FLUSH SMS Accepted 

FLUSH SMS Accepted 

# records found on FLASH 

Number of records found on FLASH 

Minimum Records to Send: # 

Number of minimum saved records to send  

GPRS Enabled: # 

State of the GPRS connection, 0 

 disabled; 

 enabled  

Time Sync: # 

Indicates time synchronization on the device, 

 not synchronized; 1 

 synchronized 

Example: FLUSH SMS Accepted. 11 records found on FLASH. Minimum Records to Send: 1. GPRS 

Enabled: 1. Time Sync: 1. 

 
 

Содержание FM3200

Страница 1: ...FM3200 User Manual V1 3...

Страница 2: ...ETER 18 6 CONFIGURATION 19 6 1 CONFIGURATOR 19 6 2 SYSTEM SETTINGS 20 6 3 GPS SETTINGS 20 6 4 GEOFENCE SETTINGS 22 6 5 GSM SETTINGS 23 6 6 GPRS SETTINGS 23 6 7 SMS SETTINGS 23 6 8 SEND PARAMETER SETTI...

Страница 3: ...38 9 4 GPRS ACCESS AND ADDRESS SETTINGS 39 APN Name ID 242 39 APN username ID 243 39 APN Password ID 244 39 Data send protocol ID 231 39 Server IP address ID 245 39 Server port number ID 246 39 9 5 GE...

Страница 4: ...n The programming must be performed using a second class PC with autonomic power supply The device is susceptible to water and humidity Warning If wrong accumulator is used the device may explode Any...

Страница 5: ...ts of standard EN 60950 1 The device FM3200 is not designed as a navigational device for boats 1 3 Legal Notice Copyright 2008 Teltonika All rights reserved Reproduction transfer distribution or stora...

Страница 6: ...M3200 device Input and output power supply cable with a 2x3 connection pins GPS antenna GSM antenna optional USB cable 2 2 Basic characteristics GSM GPRS features Teltonika TM1 dual band module 900 18...

Страница 7: ...otocol support 15000 record storing CE and E mark certified 2 3 Mechanical features Part name Physical specification Technical details Navigation LED LED Power supply 10 30 V DC 12 W Max Energy consum...

Страница 8: ...accumulator age number of charge discharge cycles For example In sleep mode a new FM3200 device s operating time is approximately 3 h 30 min Operating time for a new FM3200 device working in normal mo...

Страница 9: ...9 3 CONNECTION PINOUT ACCESSORIES 3 1 SIM card insert scheme...

Страница 10: ...stalled 1 Hotfix KB918365 usbser sys 5 1 2600 2930 2 Hotfix KB935892 usbccgp sys 5 1 2600 3116 After installing the HotFixes reboot your PC Power up the FM3200 and connect it to the computer Found New...

Страница 11: ...Click Finish The installation of FM22XX Port is completed Immediately after the end of the installation the new wizard for FM22XX GPS will appear Repeat all the steps as in previous installation MS Wi...

Страница 12: ...s switched on permanently 3 5 Status LED When device has uploaded firmware Status LED should blink If LED does not blink it means that device does not function 3 6 Socket 2 3 Figure 6 2 3 socket pinou...

Страница 13: ...or type FM3200 creates two COM Ports FM32XX Port which can be used as system port to flash firmware and configure the device and FM32XX GPS as GPS NMEA 0183 output at 9600 baud rate Figure 9 COM Ports...

Страница 14: ...e Digital inputs are used to read this information Figure below shows how to connect alarm button door sensor etc Figure 10 Panic button connection In cases when sensor output signal is negative an ad...

Страница 15: ...r when output is OFF More details about relays can be found below Figure 12 Immobilizer relay connection Relays A simple automotive relay is used to invert input signal or to immobilize engine starter...

Страница 16: ...PC with USB cable Launch FM Updater select COM port click connect and update Update process may take several minutes Figure 14 FM updater screen Updating firmware via GPRS Firmware can also be update...

Страница 17: ...er necessary parameters in the fields Server IP 212 47 99 62 Server port 5009 Module number is GSM number of FM SIM in worldwide standard for example 370XXXXXXXX Enter your APN APN chap login and pass...

Страница 18: ...ode standby mode under two conditions FM3200 does not detect movement FM3200 does not send or receive any data for 5 minutes This means that if coordinate recording interval is less than 5 minutes FM3...

Страница 19: ...nd one extra profile stored in Flash no 0 which cannot be edited by the user Profile from Flash no 0 is used by system and cannot be selected as active while profile from Flash no 1 is fully editable...

Страница 20: ...n Time based acquire interval If so FM saves record to memory If not FM checks if the distance from last record to current record is equal or higher than Distance based acquire interval If so saves th...

Страница 21: ...rds are being acquired when the distance between previous coordinate and current position is greater than defined parameter value Entering zero disables data acquisition depending on distance Angle ba...

Страница 22: ...d to enter the area while track 2 does not Figure 17 Geofence border Shape can be rectangular or circle Priority priority of Geofence event low high or panic These levels define priority of event info...

Страница 23: ...or GPRS session CHAP or PAP If any of these is used APN should be entered as APN c or APN p I e if operator is using APN internet with CHAP authentification it should be entered as internet c Informat...

Страница 24: ...mation about last 24 collected points with interval between them defined in time step field SMS sending schedule is set in SMS Week Time tab 24 Coordinates SMS decoding is described in FM4100 FM2100 a...

Страница 25: ...r Voltage 2 Voltage mV 67 Battery Voltage 2 Voltage mV 68 Battery Current 2 Battery charge current mA 0 if external power off 69 GPS Power 1 GPS antenna states 0 short circuit 1 connected 70 PCB Tempe...

Страница 26: ...ag and sends event packet immediately to the server by GPRS Panic priority triggers same actions as high priority but if GPRS fails it sends AVL packet using SMS mode if SMS is enabled in SMS settings...

Страница 27: ...d Low level thresholds Table below defines all available values of I O settings Priority low high High level maximum threshold Low level minimum threshold Generate event on interval enter on interval...

Страница 28: ...28 Figure 24 Event generation according hysteresis algorithm...

Страница 29: ...space password space command Example asd 123 getgps 7 2 SMS command list Command Description Response getstatus Modem Status information Yes getweektime Current device time Day of Week and amount of...

Страница 30: ...ODE 0 TCP 1 UDP No getstatus Response details Description Data Link Indicate module connection to server at the moment 0 Not connected 1 connected GPRS Indicate if GPRS is available at the moment Phon...

Страница 31: ...le Last Configuration was performed on 2010 4 15 5 45 19 getgps Response details Description GPS Indicates valid 1 or invalid 0 GPS data Sat Count of currently available satellites Lat Latitude Last g...

Страница 32: ...SMS 2 NOGPS 0 0 GPS 3 SAT 7 RS 7 getio Response details Description DI Digital Input state DO Digital Output state Example DI1 0 DI2 0 DO1 0 DO2 0 readio Response details Description ID IO element ID...

Страница 33: ...MODE 0 TCP 1 UDP Parameters are separated by comma no spaces needed In case you don t need to enter parameter Login Pass do not put space simply put comma and write next parameter Example opa opa flus...

Страница 34: ...our sales manager to get terminal After launching terminal choose baud rate 115200 and hardware control none Select COM port which is assigned to FM22XX Port Click on Start Log button and save a new f...

Страница 35: ...2 Data acquisition and sending parameters Time based acquire interval ID 11 Time interval in seconds indicating condition to acquire new record 0 disabled Minimum value Maximum value Recommended value...

Страница 36: ...alue Maximum value Recommended value Goes with depends on parameters Value type 1 30 1 Time based acquire interval ID 11 Distance based acquire interval ID 12 GPRS Data send week time schedule ID 272...

Страница 37: ...open does not close it If value is 1 it will work as day minutes are defined in rest of the bytes Day s minutes are defined by 18 bytes 144 bits Every n th bit beginning from the first bit LSB and end...

Страница 38: ...sed in every SMS that is sent to device Example ab123 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 5 char string SMS User login ID 252 Server Number I...

Страница 39: ...h depends on parameters Value type Empty 6 char string APN Name ID 242 APN username ID 243 S8 6 Data send protocol ID 231 Parameter defines GPRS data transport protocol Module can use TCP or UDP trans...

Страница 40: ...ority 4 bit Zone entering event 5 bit Zone leaving event 6 31 bits reserved Example Value to set 51 integer is M 00110011 L where GeoFence Zone shape is Rectangular priority of 1 Zone entering event i...

Страница 41: ...ID 034 If shape is rectangular then ID 034 is right upper corner Y coordinate in WGS If shape circle ID 034 is not used Minimum value Maximum value Recommended value Goes with depends on parameters Va...

Страница 42: ...ID 301 Parameter defines IO property type of priority 0 is low 1 high 2 panic 3 security priority type Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 3 0 I...

Страница 43: ...sample length to average If no averaging needed default value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2147483648 1 IO 1 property parameter ID 3...

Страница 44: ...the engine Check if this is not an ACC wire when key is in the first position most electronics of the vehicle are available Check if power is still available when you turn off any of vehicles devices...

Страница 45: ...is displayed in a picture below area colored green Figure 28 Correct placement of FM3200 10 6 Module Installation Module should not be seen or easily reached Module should be firmly fixed to the surf...

Страница 46: ...00 view dimensions figure added 4 100211 0 4 New Skytraq GPS module details added 5 100402 0 5 Movement sensor s Start move timeout parameter s description added 6 100423 0 6 Data acquisition info upd...

Отзывы: