Chapter 8: Electrical Specifications
AC Power Input
Voltage
TLS-4A: 115 VAC
±
15%
Frequency
49 to 61 Hz
Current
TLS-4A: 0.2 A maximum (nominal line voltage)
Fusing
0.25 A 5 x 20 mm slow blow
Unit dissipation
20 Watts maximum
Telephone Line Circuit (Loop Start)
On-hook voltage
-48
±
5 Volts (Tip positive referenced to Ring)
Short circuit loop current
< 30 milliamps
Minimum loop current
18 milliamps with a 500-ohm loop
Transmission Specifications
Nominal impedance
900 ohms
Insertion loss
Switchable between 3.4 dB and 16 dB
±
2 dB @ 1 kHz
when two lines are connected
Ring Source
Ring voltage
78 VAC
±
10% AC @ 20 HZ sinewave
Ring frequency
Selectable 20, 25, 30, 60
±
5% Hz
Drive capacity
Up to 5 ringer equivalents (5 REN) total @ 20 HZ
sinewave
Ring termination on answer
Within 250 ms
Ring waveform
Selectable step approximated sine or square wave
DTMF Detection
Frequency accept
±
(1.5% + 2 Hz)
Frequency reject
±
3.5%
Tone-on time
40 ms minimum
Tone-off time
40 ms minimum
Amplitude
+4 to -18 dBm per frequency
Twist
6 dB or less
Rotary Dialing Detection
Rate
8 to 22 PPS
Percent break range
40% to 80% (LSSGR 6.3.4.6)
Break time
18 ms minimum, 100 ms maximum
Make time
9 ms minimum, 75 ms maximum
Interdigit time
300 ms minimum
End-of-digit detection
100 ms minimum
Loop Current Detect
Minimum off-hook current
15 mA
Maximum on-hook current
10 mA
Off-hook detect time
100 ms max
On-hook detect time
>Flash
Hook flash detect time
300 - 1100 ms (must detect)
<280 ms > 1120 must not detect
Telephone Line Simulator 4A
Page 44