![telsiu altas START-S3XL Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/telsiu-altas/start-s3xl/start-s3xl_instruction-manual_1084360006.webp)
START-S3XL
Technical Manual
-6-
2.3
Connection of the FLASHING LIGHT 230 Vac
Flashing light complete
with intermittence circuit board
Flashing light complete without intermittence circuit board
DIP 4 - ON
ON
2
1
4
3
5
If you plan to use the photocells test,
or a 24V light, this connection cannot be used.
!
2.4
Connection of one 24V gate open and moving LIGHT
DIP 10
ON
Fix Light
ON
CTS
2
1
4
3
6
5
8
7
10
9
12
11
If you plan to use the photocells test, or a
24V light, this connection cannot be used.
!
2.5
Connection of the COURTESY light
LIGHT
230 Vac
DIP 4 - OFF
ON
CTS
2
1
4
3
6
5
8
7
10
9
12
11
17 18 19
20 21
3 4 5
3 4 5
20 21
3 4 5
2.6
Power supply of the ACCESSORIES
Terminal board 10 (-) / 11 (+)
Voltage:
12 Vdc
Maximum current:
50 mA
Put
JUMPER
JAC/DC
as shown
in the picture
Terminal board 10 (-) / 19 (+)
Voltage:
24 Vdc
Maximum current:
300 mA
8 9 10 11 12 13 14 15 16 17 18 19
Terminal board 18 / 19
Voltage:
24 Vac
Maximum current:
300 mA
Put
JUMPER
JAC/DC
as shown
in the picture
+
-
- +
!
!
AC DC
AC DC