Using the unit improperly and performing repairs or modifi cations personally will void the warranty. The producer 

declines any responsibility for damages due to inappropriate use of the product and due to any use other than the 

use the product was designed for. The producer declines any responsibility for consequential damages except civil 

liability for the products.

Every programming and/or every maintenance service should be done by qualifi ed technicians.

1.1 

Safety precautions

Introduction

The START-S3XL electronic control unit is used to control the movement of entrances, swinging gateways, rolling 

gates and automatic doors. It can be connected to a hydraulic or electromechanical actuator equipped with an 

asynchronous, single-phase motor operating at a voltage of 230 Vac.

1.2 

Field of application

1.3 

Type of installation

These two simple diagrams show only one of the possible applications for this control unit. The risks inherent to 

the “MACHINE” and the user’s requirements must be analyzed in depth in order to establish how many elements 

need to be installed. All photocells have a system of synchronism that makes it possible to eliminate interference 

between two pairs of photocells (for other details, see the instructions for the photocells). In the diagram, the pair of 

photocells “Photo A” (considered in this control unit) has no effect during opening while it causes a total inversion 

during closing. 

“Photo A2”

 is connected in series to 

“Photo A”

.

Application on sliding automation

Application on swinging automation

FOTO A

FOTO A

FOTO A2

We recommend to install a STOP switch which stops immediatelly the gate. The switch has a normally close contact 

which opens the contact when it is working. See Par. 2.7

Dimensions

87 x 126 x 40

mm

Weight

0.46

Kg

MAX power of single motor 

1

750

4

HP

W

A

MAX power of signal light 230 Vac

40

W

MAX absorption with clean contact

2

A

MAX absorption 24 Vac/dc

300

mA

MAX absorption 12 Vdc

50

mA

1.4 

Technical features

-3-

Содержание START-S3XL

Страница 1: ...4 15 16 17 18 19 230 Vac 230 Vac Lamp Lamp MOT common MOT close MOT open Antenna Com 1 and Antenna Com 2 12 24Vdc 12 Vdc STOP FOTO LSO LSC START Pedestrian 24 Vac 24 Vac dc 20 21 Light Fototest Light...

Страница 2: ...scription 1 2 Field of application 1 3 Type of installation 1 4 Technical features 2 Installation 4 2 1 Diagram of the control unit and electrical connections 2 2 Description of the electrical connect...

Страница 3: ...one of the possible applications for this control unit The risks inherent to the MACHINE and the user s requirements must be analyzed in depth in order to establish how many elements need to be insta...

Страница 4: ...ncreases pause time 2 1 Diagram of the control unit and electrical connections 2 Installation Connection of the VOLTAGE line 230 Volt Single phase alternate current The control unit power supply line...

Страница 5: ...for all inputs services safety devices coaxial antenna braid Com2 12Vdc 10 Output 12 24 Vdc See Phar 2 6 Common 2 12Vdc 11 Output 12 Vdc maximum current 50mA positive Stop 12 STOP input Foto 13 Input...

Страница 6: ...4 3 6 5 8 7 10 9 12 11 If you plan to use the photocells test or a 24V light this connection cannot be used 2 5 Connection of the COURTESY light LIGHT 230 Vac DIP 4 OFF ON CTS 2 1 4 3 6 5 8 7 10 9 12...

Страница 7: ...input is NOT used put the DIP 5 on ON If the input SAFETY EDGE is not used make a link 22 23 2 8 Connection of LIMIT SWITCHES LSO and LSC The gure shows the connection of both limit switches however o...

Страница 8: ...must repeat the times learning operation with the START com mand The TEST function is compatible with lower devices for example TRANSCEI VER so the gate can have a delay when opening The TEST can be d...

Страница 9: ...Connect the 3 WIRES PHOTO BEAM POWER SUPPLY TX PHOTOCELL POWER SUPPLY RX PHOTOCELL Photocell receiver N C contact terminals Bring JUMPER AC DC as shown in the picture Voltage 24 Vdc Maximum current 30...

Страница 10: ...stop close stop logic Closes again automatically at the end of the pause time 3 OFF closes again when turned on A complete opening pause and closing cycle is run ONLY if the au tomation is in the open...

Страница 11: ...OMPLETE ROLLING CODE FUNCTION PRESS THE BUTTON WHEN YOU ARE LEARNING THE PARTIAL OPENING COMMAND THE L E D WITH PARTIAL ROLLING CODE WILL FLASH ONE TIME WHILE WHILE WHEN THE ROLLING CODE IS COMPLETE T...

Страница 12: ...le to delete a single wireless control code ON 2 1 4 3 5 P L1 5 Turning on and programming the unit When the electronic circuit board is turned on if everything has been connected properly the red TES...

Страница 13: ...RT to start closing The automation starts in CLOSING mode 8A On SLIDING press START to de ne the point in which the automation is to start decelerating The automation DECELERATES 8B On SWINGING withou...

Страница 14: ...start closing The automation starts in CLOSING mode 7 Wait for the automation to stop automatically The automation is in the CLOSED position 8 Set the switch DIP 1 to OFF to return to normal opera ti...

Страница 15: ...ns PROBLEM The electronic circuit board does not work the TEST signal light does not ash SOLUTION Check the 4A and 160mA fuses PROBLEM The 160mA fuse is burnt out SOLUTION Check the connections and ma...

Страница 16: ...rtain voltage limits Reference to harmonized standards EN 60335 1 2004 108 CE EEC DIRECTIVE 2004 108 CE ISSUED BY THE EUROPEAN COUNCIL on December 15 2004 harmonizing the legislation of the member cou...

Отзывы: