QUICK-START INSTALLATION GUIDE
Configuring I/O
Connect your SDI source(s) to the SDI input(s) on the rear panel. Select “I/O” then, “Reference Clock”, then
AES67/PTP. The Reference Clock indicator will show AES67/PTP as the primary clock source and a green
light will indicate the SDI AoIP Node is locked to the PTP Master. A secondary sync source can be selected
is desired. The internal clock is selected in the example.
See Figure 6
.
Figure 6 - Reference Clock
Select “AES67”, then use the dropdown menu under “AES67 Out Routing” to select the AES67 channel
destinations for the SDI Inputs.
See Figure 7
.
An AES67 Output dropdown is
shown open in Figure 7
. The router allows you to select any of the SDI
input pairs (or any of 8 x AES67 pairs) to be routed to the network.
Figure 7 - SDI Routing to AES67 outputs