Chapter 5 |
17
Remote User Interface
In the center of the Input Meter section, you’ll find the following numeric readouts:
♦
At the top, the
Average Integrated Loudness display
(D) shows the average loudness measurement since the last input
meter reset
¸
Either LUFS or LKFS will be indicated depending upon the current profile
♦
In the middle is the
Dialog Loudness display
(C) which shows the average loudness measurement of the program dialog only
♦
At the bottom, the
True Peak display
(B) shows the highest recorded peak on either channel since the last Input Meter reset
♦
Beneath the True Peak display are the
Pause
and
Reset buttons
¸
Clicking on the
Pause button
(F) will temporarily stop loudness measurements on the Input Meter; clicking it again
will un-pause the meter and resume loudness measurement
¸
Clicking on the
Reset button
(G) restarts loudness measurements on the Input Meter
The
meters on the right side of the Input Meter section
(E) provide the following information:
♦
The
wide blue bars
indicate input loudness measurements in three different integration times: Momentary (M), a
400ms reading; Short Term (ST), a 3s reading; and Mid Term (MT), a 10s reading
♦
The
numeric values
at the top of the Momentary, Short Term, and Mid Term meters indicate their respective maximum
short-term levels since the Input Meter was last reset
♦
The
fine white line with a triangle
shows the target output level (as set by the Target Loudness control)
Содержание LINEAR ACOUSTIC ARC
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 22: ......
Страница 37: ...Chapter 5 27 Remote User Interface Figure 5 12 PTP menu...
Страница 38: ......
Страница 48: ......
Страница 60: ......
Страница 64: ......
Страница 67: ...Chapter 11 57 Addendum 1 Figure A1 2 Logging menu...
Страница 68: ......
Страница 70: ......
Страница 71: ......