Telonics TCA-500 Combo Amp
19
PB-009289 Rev _ PRELIMINARY
TCA-500
C
OMBO
A
MP
C
ONTROL
F
UNCTIONS
,
J
ACKS
,
&
I
NDICATORS
:
R
EAR
P
ANEL
AC (MAINS) Power
Input
110-120VAC input*. Standard C13 plug on a 18 AWG cord is recommended.
The power input is fused with an 8 amp 250VAC 5x20mm ceramic Slow Blow
fuse.
Main Fuse (rear) –
The AC mains protection fuse is located on the
rear panel. It is in a fuse drawer directly above the AC mains power
cord socket and below the Off/On switch. Use a small screwdriver to
release the spring latch on each side of the drawer to release the fuse
drawer.
WARNING - Before checking this fuse ALWAYS ensure the
combo is disconnected from the mains supply.
If tests / a visual inspection of this fuse indicate it is open circuit,
take caution, your combo may have developed a fault.
ONLY replace the fuse with the EXACT type – Ceramic 8 Amp :
5 x 20mm : 250 Volt.
Note: If the fuse should blow immediately after being replaced DO
NOT try it again, this could cause more damage; return the combo
to Telonics for testing and repair.