background image

tellsystem.eu

EasyCon GSM

page 8.

TellSystem Communication

Programming installation settings:

ssssssss = the eight “s” letters determine whether you wish to send sMs to the phone numbers to be notified. If “s”=1 the device 
sends sMs; if 0 it does not. If you leave it blank, previous settings remain.
vvvvvvvv = the eight “v” letters determine whether you wish to send VoICe message to the phone numbers to be notified. If “s”=1 
the device makes a voice call; if 0 it does not. If you leave it blank, previous settings remain.

tttt = types of the two inputs. “t” can be a value between 0 and 5, a letter “i” (= inverted) or “n” (= non-inverted) needs to be put 
before the value.  e.g.: i1 = normal inverted input

0

Input off

1

24 hour normal input

2

not used

If you put an “i” before the number, the input will be inverted. 
kk = type of output. “k” = a value between 1 and 7.

(K)

Mono/BI stable

Alarm control

Caller ID control

1

BI stable

oFF

oFF

2

Mono

on

oFF

3

BI

on

oFF

4

Mono

oFF

on

5

BI

oFF

on

6

Mono

on

on

7

BI

on

on

e.g.: Input1 sends sMs to 2nd and 3rd phone number, Input2 sends voice message to 1st phone number, input1 is 24 hour normal, 
input2 is inverted normal. the output is monostable, controlled with alarm. 

1234o0110000000000000,0000000010000000,,,,n1i1n0n0,22

Содержание EasyCon GSM

Страница 1: ...EasyCon GSM Installation manual...

Страница 2: ...t settings page 4 Input settings page 5 Power monitor page 5 Tamper page 6 Life signal page 6 SMS forward page 6 Description of voice calls page 6 Description of SMS page 7 Calendar of events page 7 E...

Страница 3: ...erferences such as electric motors or transformer of the alarm system Do not install device in wet or high humid places Connection of the antenna You may connect the antenna to a SMA plug In case of p...

Страница 4: ...a regular mobile phone or you may view edit the SIM card s address book in the Caller ID tab First you need to upload it with the Read button then after editing write it in with the Send but ton The...

Страница 5: ...restore also In case of SMS Other Restore mes sage is sent Siren sound In case of VOICE call emits a siren sound 20 30 seconds Sending a voice message In case of VOICE call it plays recorded voice Att...

Страница 6: ...required You do not need to listen to the siren sound voice message answering the phone means confirmation Avoid ing voicemail confirmation your ringtone time needs to be set shorter than your voicema...

Страница 7: ...the programme where it is displayed as a graph When performing maintenance you can check for constant signal strength The module is capable of storing signal strength data for the last 20 years SMS p...

Страница 8: ...tttt types of the two inputs t can be a value between 0 and 5 a letter i inverted or n non inverted needs to be put before the value E g i1 normal inverted input 0 Input off 1 24 hour normal input 2 N...

Страница 9: ...onitoring station the use of high gain antenna is recommended since perfect transmission requires suf ficient signal strength above 60 Monitoring station signals Input1 Input2 Power supply Periodic li...

Страница 10: ...e programming cable if the name of the device shows click start in the telephone tab enter the phone numbers you wish to notify then fill in the other tabs finally transfer the configuration and save...

Страница 11: ...tellsystem eu EasyCon GSM page 11 TellSystem Communication CE certificate...

Отзывы: