Description and functions of the device

• 

the GsM communicator may be used as a complement to alarm control systems as a 2 input GsM transmitter. 

• 

capable of sending voice or sMs messages to 8 phone numbers.  Voice messages with a length of up to 8 seconds can be sent 
concerning the 2 inputs and power failure. An extra identification message may be recorded (up to 16 seconds), which is played 
before the alarm message.

• 

the open collector (oC) output of the device may be used for control with caller ID. 

• 

capable of forwarding sMs messages received by the sIM card to a preset phone number.

• 

monitors power failure and GsM signal strength; GsM signal strength can be read out and drawn up as a one-hour resolution 
graph with the programming software. 

• 

possesses a 16.000 event list, which records signals, GsM status, incoming calls and phone numbers. 

• 

PC programming is possible with ProRead software and optional programming cable!

Description of the terminal block

I2, C, I1

Input2 and Input1 controlled by short-circuit or cut in relation to CoM port

o

output of the module: oC=open collector

+, -

Power supply: += 9-18 VDC; -= GnD

Installation instructions

• 

Check signal strength with your mobile. It is possible that signal strength is not sufficient at the desired place. If so, modify device 
location before installation.

• 

Locate device far from electromagnetic interferences, such as electric motors, or transformer of the alarm system.

• 

Do not install device in wet or high humid places.

• 

Connection of the antenna: You may connect the antenna to a sMA plug. In case of poor signal strength use a higher gain an-
tenna.

• 

Disable PIn requirement, voice mail, and call notification on your sIM card.

• 

occasionally a newly bought sIM card needs to be activated (usually by making an outgoing call).

• 

Caller ID function needs to be activated on your sIM card by the Mobile service Provider (with some models it is not activated 
by default).

• 

Insert sIM card.

• 

Connect antenna to device.

• 

Connect as indicated.

• 

Device is ready to be connected to power supply. Make sure that the power supply is sufficient for the operation of the device. 
the module’s resting current is 20mA, but may reach 300mA during communication.

• 

After connecting to the power supply, the red LeD goes on, which indicates that the device is trying to contact the GsM tower 
(up to 1 min).

• 

When the red LeD light goes off and the green LeD is flashing, the module is ready for operation and has connected to the net-
work. the number of flashes indicates signal strength.

• 

For programming the power supply needs to be connected.

LED signals

LeD status = green
ACt LeD = red
number of flashes: number of LeD flashes between the breaks.

only green LeD flashes

no error, GsM module connected, the number of LeD flashes shows signal strength. 
1..2=poor signal strength, 3=sufficient, 4..5=excellent

Green LeD on

GsM module’s connection rejected.

Red LeD on

shows initialization on start-up, otherwise an event message is being sent (sMs, voice 
call).

Содержание EasyCon GSM

Страница 1: ...EasyCon GSM Installation manual...

Страница 2: ...t settings page 4 Input settings page 5 Power monitor page 5 Tamper page 6 Life signal page 6 SMS forward page 6 Description of voice calls page 6 Description of SMS page 7 Calendar of events page 7 E...

Страница 3: ...erferences such as electric motors or transformer of the alarm system Do not install device in wet or high humid places Connection of the antenna You may connect the antenna to a SMA plug In case of p...

Страница 4: ...a regular mobile phone or you may view edit the SIM card s address book in the Caller ID tab First you need to upload it with the Read button then after editing write it in with the Send but ton The...

Страница 5: ...restore also In case of SMS Other Restore mes sage is sent Siren sound In case of VOICE call emits a siren sound 20 30 seconds Sending a voice message In case of VOICE call it plays recorded voice Att...

Страница 6: ...required You do not need to listen to the siren sound voice message answering the phone means confirmation Avoid ing voicemail confirmation your ringtone time needs to be set shorter than your voicema...

Страница 7: ...the programme where it is displayed as a graph When performing maintenance you can check for constant signal strength The module is capable of storing signal strength data for the last 20 years SMS p...

Страница 8: ...tttt types of the two inputs t can be a value between 0 and 5 a letter i inverted or n non inverted needs to be put before the value E g i1 normal inverted input 0 Input off 1 24 hour normal input 2 N...

Страница 9: ...onitoring station the use of high gain antenna is recommended since perfect transmission requires suf ficient signal strength above 60 Monitoring station signals Input1 Input2 Power supply Periodic li...

Страница 10: ...e programming cable if the name of the device shows click start in the telephone tab enter the phone numbers you wish to notify then fill in the other tabs finally transfer the configuration and save...

Страница 11: ...tellsystem eu EasyCon GSM page 11 TellSystem Communication CE certificate...

Отзывы: