8820 MSR Chassis
Front Panel
Equipment Overview
3-3
PN 76.8820IM30-A
Tellabs 8820 Multi-service Switch Router System Installation
LED Indicators
LED test functions are provided for all LED types on the system panel. When power is
applied to the chassis, the power A and B LEDs, the fan LED, the temperature LEDs, the
stat LED, the critical, major, and minor status LEDs are illuminated red. The power LEDs
are illuminated green for the duration that the ACO button is depressed.
Environmental LEDs
The 8820 MSR environmental LEDs indicate status of the fans, system temperature, and
operational status
.
Alarm LEDs
The 8820 MSR alarm LEDs indicate severity of problems detected by the system. Severity is
immediately apparent as a result of interpreting the LED colors shown in the CRT, MAJ,
and/or MIN LEDs
.
Table 3-1
Environmental LEDs
LED
LED Color and Probable Causes
Off
Green
Red
Temp
Temperature within
acceptable limits
Not applicable
❑
Temperature exceeds
preset threshold
❑
LED test
Fan
Fans operating nor-
mally
Not applicable
❑
LED test - single or
multiple fan failure
Pwr A, Pwr B
(DC power)
No power supplied
❑
-48 VDC and
return are present
❑
LED test
Not applicable
Pwr A, Pwr B
(AC power)
No power supplied
❑
Power A - AC
present
❑
Power B - Not
applicable
Not applicable