tell ecoLINE Скачать руководство пользователя страница 4

 

4

 

Voice dialer support 

One main characteristic of voice dialers is that they used to start playing the message if 
they detect no ringtone on the line in a certain time. 
By enabling this function, the module generates a simulated tone signal until the call is 
received. This way can be avoided that the voice dialer starts to play the message before 
receiving the call. By default, this function is disabled. To enable/disable voice dialer 
support, connect a wired phone device to the module’s “TIP-RING” terminals, then pick 
up the receiver and dial the following: 

  to enable voice dialer support: 

0000

1

#

 

  to disable voice dialer support: 

0000

0

#

 

After entering the activation or deactivation command, the module confirms the execution 
by emitting a beep through the phone. 

 

Configuring by SMS commands  

It is possible to configure the module by sending the appropriate command in SMS to the 
module’s phone number from the phone number configured as SUPERUSER. After 
receiving a command, the module sends response SMS, except for SUPERUSER 
registration. The SMS commands are the following: 

 

SUPERUSER# 

The module sets the sender’s phone number as Superuser. 

The 

module accepts this parameter only if no Superuser has 
been set before! 

No response SMS is sent for this command! 

SU=# 

Deletes the current Superuser. The module accepts this 
command only from previously set Superuser phone number. 

SFW=

phone number

#

Sets the phone number where incoming SMS messages will be 
forwarded. 

SFW=# 

Deletes the phone number where incoming SMS messages are 
forwarded. 

VDS=1# 

Enable voice dialer support. 

VDS=0# 

Disable voice dialer support. 

GMIC=

X

Adjusts the microphone volume (outgoing CID volume). 
Substitute X with a number between 0…15. Default setting: 3. 

GSPK=

X

Adjusts the speaker volume (incoming HSK/ACK volume). 
Substitute X with a number between 0…100. 
Default setting: 50. 

 

GSM signal strength query 

To get the current GSM signal strength, press shortly the pushbutton found on the 
module. Thereafter the number of green blinks of the LED found on the module indicates 
the signal level on a 3-point scale. 

 

Service port 

The USB service connector found on the module serves for diagnostics and eventual 
firmware upgrade or in-call volume adjusting. 

Содержание ecoLINE

Страница 1: ...ecoLINE GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2 0 and higher Document version 1 31 22 11 2013...

Страница 2: ...gs 3 4 Volume adjusting application 5 5 LED signals 6 6 Wiring diagram 6 7 Installation guide 6 7 1 Mounting 6 7 2 Putting into operation 7 8 Technical details 7 8 1 Technical specification 7 8 2 Gene...

Страница 3: ...upport GSM signal strength query using the function button 3 Settings Setting the phone number for SMS forwarding function The module can forward the SMS messages received on the inserted SIM card to...

Страница 4: ...MS except for SUPERUSER registration The SMS commands are the following SUPERUSER The module sets the sender s phone number as Superuser The module accepts this parameter only if no Superuser has been...

Страница 5: ...ware Copy the software form the module s USB storage to PC then start it Connect the module to USB The software connects to the module automatically then Read and Set buttons become available Read the...

Страница 6: ...e changed before mounting the device Do not mount the unit in places where it can be affected by strong electromagnetic disturbances e g in the vicinity of electric motors etc Do not mount the unit in...

Страница 7: ...the power supply is sufficient for the load of the module The quiescent current of the module is 110mA however it may increase up to 400mA during communication 8 Technical details 8 1 Technical speci...

Отзывы: