1 Application area 

Adaptation to GSM network of alarm control panels which are equipped with PSTN line 
communicator to send reports to monitoring station using DTMF based protocols 
(Contact ID, Ademco Express); the module makes possible the installation of such alarm 
systems in places where PSTN line is not available but reporting to monitoring station is 
requested. The module may also be used as phone line substitute, GSM line simulator; 
by connecting a wired phone device to the module, incoming and outgoing calls can be 
performed through the GSM network. 

2 Functions 

  Adaptation to GSM network 

  Forwarding of incoming SMS messages to one adjustable phone number 

  SMS forward limit (max. 5 messages/12 hours) 

  Call duration limit (max. 25 minutes/call) 

  Voice dialer support 

  GSM signal strength query using the function button 

3 Settings 

 

Setting the phone number for SMS forwarding function 

The module can forward the SMS messages received on the inserted SIM card to one 
adjustable mobile phone number. To adjust the phone number, connect a wired phone 
device to the module’s “TIP-RING” terminals, then pick up the receiver and dial the 
following: 

  to set new phone number: 

 

1234

phone number

#

 

  to delete phone number: 

 

1234

#

 

After setting or deleting the phone number the module confirms the execution by emitting 
a beep through the phone. When a new phone number is set, the module sends as a 
confirmation a test SMS to the given phone number with the following message: „SMS-
Forward settings accepted”. 
 
Attention! The module does not forward SMS messages received from the superuser 
phone number! 
 
SMS forward limit: the module is equipped with automatic limitation of outgoing SMS 
messages. The function allows forwarding of 5 messages/12 hours. 

Содержание ecoLINE

Страница 1: ...ecoLINE GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2 0 and higher Document version 1 31 22 11 2013...

Страница 2: ...gs 3 4 Volume adjusting application 5 5 LED signals 6 6 Wiring diagram 6 7 Installation guide 6 7 1 Mounting 6 7 2 Putting into operation 7 8 Technical details 7 8 1 Technical specification 7 8 2 Gene...

Страница 3: ...upport GSM signal strength query using the function button 3 Settings Setting the phone number for SMS forwarding function The module can forward the SMS messages received on the inserted SIM card to...

Страница 4: ...MS except for SUPERUSER registration The SMS commands are the following SUPERUSER The module sets the sender s phone number as Superuser The module accepts this parameter only if no Superuser has been...

Страница 5: ...ware Copy the software form the module s USB storage to PC then start it Connect the module to USB The software connects to the module automatically then Read and Set buttons become available Read the...

Страница 6: ...e changed before mounting the device Do not mount the unit in places where it can be affected by strong electromagnetic disturbances e g in the vicinity of electric motors etc Do not mount the unit in...

Страница 7: ...the power supply is sufficient for the load of the module The quiescent current of the module is 110mA however it may increase up to 400mA during communication 8 Technical details 8 1 Technical speci...

Отзывы: