xE70-915 RF Module User Guide
1VV0301106
rev.3 – 2015-03-04
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved.
Page 13 of 34
3.6.
DC Specifications
Measured on DIP interface with T = 25°C, under 50
Ω
impedance connected to RF port and
default power register setting if nothing else stated.
Max limits apply over the entire operating range, T=-40°C to +85°C, Vdd=2.3V to 3.6V and
all channels.
Characteristics xE70-915
Min.
Typ.
Max.
Unit
Power Supply (V
DD
)
+2.3
-
+3.6
V
Consumption at 3.6V
Maximum output power 500mW
(+27dBm)
390
420
mA
Reception
25
30
mA
Stand-by (32.768 kHz On)
2
3
µA
I/O low level
GND
-
0.2x V
DD
V
I/O high level
0.8x V
DD
-
V
DD
V