![Telit Wireless Solutions WE866E4-P Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/telit-wireless-solutions/we866e4-p/we866e4-p_at-commands-reference-manual_1083755022.webp)
WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0
22
2018-02-16
PRELIMINAR
Y
Response
, describes the responses and remarks for Configure UART command.
Synchronous Response
, describes the synchronous responses and remarks for Configure UART
command.
Example
ATB=115200,3,0,1
OK
Table 4 Configure UART Parameters
Parameters Mandatory/Optional
Value
Description
BaudRate
Mandatory
Value range:
110-921600
Format:
Integer
Default value:
115200
It specifies the UART parameters
Bits per
Character
Optional
Value range:
0-3
Format:
Integer
Default value:
3
It specifies the bits per character.
Parity Mode Optional
Value range:
0-3
Format:
Integer
Default value:
0
It specifies the mode of the parity being
used.
Stop Bits
Optional
Value range:
0-3
Format:
Integer
Default value:
1
It specifies the number of stop bits.
Table 5 Configure UART Response
Responses
Remarks
OK
Success.
ERROR
If parameter is not valid.
Table 6 Configure UART Synchronous Response
Responses
Remarks
OK