Not Subject to NDA
•
Slave mode only (hard-coded address = 0x10)
•
Fast mode (up to 400 Kbps)
•
7-bit address
•
255-byte buffer
•
The module operates in the polled mode (with the host as the master.)
Transmit
-
The host must be able to read several packets each report cycle. A minimum pause of 2
ms is required between reads to allow the module to fill the buffer. A longer delay is
permissible. For example, if the report cycle is 1 second, set the polling sleep time to 500
ms for the next output interval to start.
The buffer will contain up to 25
4 data bytes plus an <LF> (x’0A”) character.
Each NMEA sentence will be terminated by the (standard) <CR-LF>
(x’0D, x’0A’)
characters, and a NMEA sentence can span buffers.
If necessary, a buffer is padded with x’0A’ characters. x’0A’ is also used for idl
e
characters.
Receive
-
The maximum length for commands sent to the module.is 255 bytes.
A minimum of 10 ms is required between packets.
Warning:
The following features are fully supported via I2C:
•
GLP mode (Enable/Disable)
•
Low Power modes supported by the module (Set and Wakeup)
•
1-PPS Sync to NMEA
Warning: On the other hand, the following features are not supported
via I2C:
•
FW Flashing
•
EPO
•
Always locate.
Further details and sample code are available under NDA from Telit MT3333 I2C
Application Note.