SL869T3-I Product User Guide
1VV0301546 Rev. 3
Page 52 of 68
2021-03-31
hermetic seal provided the factory conditions are less than 30°C and less than 60% and
the humidity indicator card indicates less than 10% relative humidity.
If the package has been opened or the humidity indicator card indicates above 10%, then
the parts must be baked prior to reflow. The parts may be baked at +125°C ± 5°C for 48
hours. However, the tape and reel cannot withstand that temperature. Lower
temperature baking is feasible if the humidity level is low and time is available. Please
see IPC/JEDEC J-STD-033 for additional information.
Additional information can be found on the MSL tag affixed to the outside of the
hermetically sealed bag.
JEDEC standards are available free of charge from the JEDEC website
Figure 13-5 Moisture-Sensitive Device Label