5.
Click on the Load button, then locate and select the software provided by Telit.
6.
Verify selections as follows:
a.
“Target device” is SQI flash
b.
“Erase NVM” is
not
selected
c.
“STA8090FG Only” is selected
d.
Output Port matched your configuration
7.
After selecting the correct configuration and the selected COM port is properly identified
(Look under Device Manager in Windows OS for COM port if cannot be
identified/found), click on “Send” to program the device.
When done, a pop up window will confirm, “Device successfully programmed”.
8.
Remove the shunt jumper from Step 1.
9.
Cycle power to EVK. Verify NMEA data is streaming out with TelitView under the