ME50
ME50
ME50
ME50----868 Demo Case
868 Demo Case
868 Demo Case
868 Demo Case User Guide
User Guide
User Guide
User Guide
1vv0300907 Rev.5 – 2012-10-15
Reproduction forbidden without written authorization from Telit Communications S.p.A.- All Rights Reserved.
Page 19 of 23
Mod. 0806 2011-07 Rev.2
9.
Select “T2 Other” in the “M-Bus Mode” panel, select “Length”, “C Field”, “M
Field”, “A Field” and “CI Field” in the “Serial Tx Format” panel and click on “Apply
Values”; wait for the settings to be applied and close the configuration window. In the
“MBus Management” window, send the “ATO” command as done previously with
the first DemoBoard. Now both modules are ready to transfer data.
10.
To illustrate data communication, an example frame containing a measured volume of
876543 liters will be used. Based on the settings applied to the first module, to send a
frame the fields to be sent to the serial port are C-Field and CI-Field, plus an optional
Data-Field. In this example, a C-Field value of 0x44 (SEND / NO REPLY) and a CI-
Field value of 0x78 (indicating a frame from a meter to a data concentrator, without
data header) is chosen; the Data-Field is composed of the byte sequence (in
hexadecimal notation) 0B 13 43 65 87, indicating a value of 876543 liters expressed
with BCD coding. The total byte sequence to send to the serial port of the first
DemoBoard is: 44 78 0B 13 43 65 87. In the “MBus Management” window of the SR
Tool instance connected to the first DemoBoard, select “Hexadecimal” in the