1vv0301515 Rev.1
Page 52 of 59
2018-07-18
Check the supported alarm indexes
AT+CALD=?
+CALD: (0)
is supported only alarm index = 0
OK
2.12.2.3.
Recurrent Alarm
Follow these commands to set up the recurrent alarm configuration.
Read the current time
AT+CCLK?
+CCLK: "18/03/12,11:28:20"
OK
Set up the alarm configuration, the alarm index <n>=0. <recur>=0 sets a recurrent alarm for all
days in the week.
AT+CALA="18/03/12,11:55:30",0,1,"Dummy",0
OK
Read the current time
AT+CCLK?
+CCLK: "18/03/12,11:45:20"
the alarm time is still not reached
OK
The Alarm time is reached, the module displays on the DTE the following URC.
+CALV: 0
alarm index is 0.
Set up the new day to simulate the passing of time
AT+CCLK="18/03/13,11:42:00+00
OK
Read the current time
AT+CCLK?
+CCLK: "18/03/13,11:44:25"
the alarm time is still not reached
OK
The alarm time is reached, the module displays on the DTE the following URC.
+CALV: 0
alarm index is 0.